Page
18
When complete readjust the gas pressure if necessary then press
to start the
tightness test:
TIGHTN’S
P1
20.01
→
Pressure at start of tightness test.
P2
20.01
→
Real time pressure reading.
TIME
119
→
Tightness default time is 2 minutes. Can be
changed via “Menu”.
When complete the display will show:
LOG
01
→
The tightness test is automatically stored in
the memory. See
Note:
below
P1
20.01
→
Pressure at start of tightness test.
P2
19.98
→
Pressure at end of tightness test.
Ð
→
Press
to print the complete test.
Viewing / printing a logged Let-by and Tightness test
Select MENU / REPORT / TIGHTN’S / VIEW
Use
or
to select the log number to be printed.
Press
/
to print the test, (or send to PC via optional Bluetooth).
Note:
The analyser’s memory can store up to 20 tightness tests. Tightness tests are logged
automatically therefore the tightness section of the memory will be full after the 20
th
tightness test is complete. Before the 21
st
tightness test can be performed the
tightness section of the memory must be cleared. To do this select MENU / REPORT
/ TIGHTN’S / DEL ALL / YES then press
.