KANE451 Overview
The
KANE451
Combustion Analyser measures carbon dioxide (CO
2
)
,
carbon
monoxide (CO) to 10,000ppm, differential temperature and differential pressure. The
direct measurement of CO
2
is achieved using a Kane designed infra-red sensing
system.
CO
2
is set to zero in fresh air automatically after the initial countdown.
If “RESET GAS ZERO” is indicated ensure that the unit is in fresh air before pressing
the button with an “Enter” symbol.
It calculates oxygen (O
2
), CO/CO
2
ratio, losses, combustion efficiency (Nett, Gross or
Condensing) & excess air.
The KANE451 Combustion Analyser can also measure CO levels in ambient air -
useful when a CO Alarm is triggered. It can also perform a Room CO Test for up to 30
minutes duration.
The analyser has a protective rubber cover with a magnet for “hands–free” operation
and is supplied with a flue probe with integral temperature sensor.
The large display shows 4 readings at a time and all data can be printed via an
optional infrared printer. The printed data can be 'live' data or ‘stored’ data.
The memory can store up to:
99 combustion tests
20 pressure tests
20 let-by/tightness tests
20 temperature tests
30 room CO tests
Two lines of 20 characters can be added to the header of printouts.
The analyser is controlled using 4 function buttons and a rotary dial.
The four buttons (from left to right) switch on and off the analyser, switch on and off
the backlight and task light, switch on and off the pump and send data to a printer or to
the memory. The buttons with UP, DOWN and ENTER arrows also change settings
such as date, time, fuel, etc. when in MENU mode.