11
Before turning the generator on, verify that the connected devices are in working
order. If the connected device suddenly stops running – turn the power off by
means of an emergency switch, disconnect the device and check it.
Starting with electric starter in the cold season
When the air temperature is lower than +5
о
С it is necessary to use the «Warming-
up» function when starting. Turn the ignition key to ON position and push the heating
button. Hold it and turn the ignition key to START position.
Do not let the simultaneous connection of two or more devices. Start of
many devices requires large power capacity. Devices are to be connected
in turns, according to its maximum allowed power. Do not connect the
consumers in first 3 minutes after the generator start.
Electric start
- Do not connect any devices before you start the engine.
- Connect the positive terminal of the battery.
- Turn the motor safety switch to ON position.
- Set the key to ON position.
- Turn the key clockwise to START position.
- After the engine launch, release the key, and it will automatically return to ON
position.
- If the engine doesn’t start after keeping the key in START position for 10 seconds, wait
15 seconds before trying start again. The battery can discharge after continuous work
of launch engine system. Leave the key in ON the position during work.
- After three minutes of the generator work, switch machine protection (Emergency
switch) in the upper position ON.
If engine does not start after three or four attempts, it may
mean that the fuel system has some air inside.
!
!
IMPORTANT!
!
!
ATTENTION - DANGER!
Do not hold the ignition key in «Warming-up» position more than
15 seconds, it may cause the failure of incandescent candles.
Disconnect all devices before stopping the generator.
Do not stop the
generator, if there are any devices connected. This may result to generator
breakdown.
!
!
IMPORTANT!