12

Fig. 5

CONTROL PANEL.

MAIN FUNCTIONS OF CONTROL BUTTONS.

Multifunction control unit

 for models KS 14200HDES ATSR and KS 14200HDES 1/3 ATSR

Generator start-up.
Generator manual start-up.

Automatic mode.
Press this button to switch the control unit to automatic 
mode.

Manual mode.
Press this button to switch the control unit to manual mode.
Press and hold down this button to disable the manual 
mode.
Generator stop.
Pressing this button stops the generator in the manual 
operation mode. With the cooling operation enabled, 
pressing this button will immediately turn off the generator.

Summary of Contents for KS 14100HDE ATSR

Page 1: ...e read this manual carefully before use Owner s Manual DIESEL GENERATOR KS 14100HDE ATSR KS 14100HDE 1 3 ATSR SILENT DIESEL GENERATOR KS 14200HDES ATSR KS 14200HDES 1 3 ATSR HEAVY DUTY diesel generato...

Page 2: ...ng Started ________________________ 17 10 Generator Start up ______________________ 18 11 Maintenance __________________________ 20 12 Recommended Maintenance Schedule _ _ _ _ _ _______ 21 13 Recommen...

Page 3: ...ke changes in the product design configuration and construction The images and drawings in this manual are for reference only and may differ from the actual components and inscriptions on the products...

Page 4: ...certified electrician in accordance with all electrical codes and regulations _Connect the electric generator to the protective ground before operation _Do not connect disconnect the generator to from...

Page 5: ...the right to warranty service _Thegeneratormustbemaintainedbytrainedandqualifiedpersonnelonly For the nearest service center please contact your local dealer or refer to the current list of service c...

Page 6: ...h wet or dirty hands 8 _Observe fire safety regulations do not operate the generator near open flame 1 2 3 6 5 4 1 _Wear protective rubber gloves when handling the battery The battery contains a dange...

Page 7: ...er from the actual components and inscriptions on the products 1 Generator 2 Packaging 3 Owner s manual 4 Optional equipment Complete set 1 _Oil filter key 2 230V plug 16 A 2 3 _230V plug 32 2P E 4 _2...

Page 8: ...age frequency workinghours NoiselevelLPA LWA dB 71 96 72 97 Power output DC V 12 8 3 12 8 3 Engine model KS 1020HD KS 1020HD Engine type diesel powered two cylinder four stroke air cooled diesel power...

Page 9: ...htly limited by circuit breakers The optimum operating conditions are ambient temperature of 17 25 C barometric pressure of 0 1 MPa 760 mm Hg and relative humidity of 50 60 Under such ambient conditio...

Page 10: ...ldbeconsideredwhenselectingagenerator Most electric tools have a start up current ratio of 2 3 This means that the operation of such tools requires a generator the power of which is 2 3 times the powe...

Page 11: ...l must comply with the operating season CONTROL PANEL Fig 3 1 Single three phase switch position 1 400V position 0 OFF position 2 230V 2 Ignition switch 3 LED display for models KS 14100HDE ATSR and K...

Page 12: ...ators is cyclic The selected mode is highlighted by the corresponding icon V this mode displays the voltage level of the generator in volts Hz this mode displays the frequency of the generator in Hert...

Page 13: ...Automatic mode Press this button to switch the control unit to automatic mode Manual mode Press this button to switch the control unit to manual mode Press and hold down this button to disable the ma...

Page 14: ...r if the error message is displayed Escape Press this button to move one menu level up and cancel the parameter change Enter Pressthisbuttononthehomepagetoenterthemainmenu Press this button in the mai...

Page 15: ...ginoperationofhighvoltageequipment Measuring devices must be installed in accordance with local and national electrical codes and regulations _ The engine and other devices must be equipped with speed...

Page 16: ...ENERATORPARAMETERS P_ 10 0KW F 50Hz I_ 10 0 10 0 10 0A L N 220 220 220V L L 220 220 220V 3 ENGINE ENGINE OILPRESSURE OILPRESSURE bar CABINTEMP HOUSINGTEMPERATURE C FUELLEVEL FUELLEVEL OILTEMP OILTEMPE...

Page 17: ...ADY NOT READY READY READY PRESTART PRESTART CRANKING STARTER CRANK INT INTERVAL BETWEEN AUTOMATIC START UPS OFTHE GENERATOR START IDLE IDLE START RUNNING IN OPERATION ONLOAD LOADED COOLING COOLING STO...

Page 18: ...s pay attentiontothecorrectpolarity plus toplus minus tominus _ Firstconnectthechargercabletothebatteryandonlythentothegenerator The generator should be connected to the mains supply by a skilled elec...

Page 19: ...he key in the ON position _After three minutes of the generator operation switch the circuit breaker circuit breaker Fig no 4 to the upper position ON Before connecting devices to the generator make s...

Page 20: ...e the power distributed to all three phases andthepowermustbebalancedatallphases Thepowerateachofthethree phasesmustnotexceed1 3ofthetotalpowerofthegenerator Thebalancetolerance shouldnotexceed20 Ifon...

Page 21: ...parts _Corrosive damage and other effects of improper storage of equipment _Damage caused by maintenance work performed by unskilled technicians Observe the instructions in this manual The generator...

Page 22: ...y Checkvoltage min 12 3V Monthly Unit Action At each start Commissioning Every 3 months or 50 operating hours Every 6 months or 100 operating RECOMMENDED OILS Motor oil significantly affects the engin...

Page 23: ...Unscrew the drain cap located on the engine under the dipstick cap with a wrench 3 Wait for the oil to drain 4 Replace the drain cap and tighten securely To add oil proceed as follows 1 Make sure the...

Page 24: ...maintenance of the air filter is necessary to maintain sufficient air flow in the carburetor The maintenance intervals should be shorter when operating the generator in dusty environments Fig 8 IMPORT...

Page 25: ...er 3 Cleanthefilterwithdieselfuel 4 Replacethefilterinthefueltank FuelFilterintheFuelLine Thisfiltermustbechangedevery100operatinghours Itislocatedunderthefueltank onthefuelhosethroughwhichfuelenterst...

Page 26: ...Thegeneratormustbestoredinadry well ventilatedareathatisfreefromdust Keep away from children Generator Long term Storage If the generator will not be used for a long time it is recommended to Drain th...

Page 27: ...the tank and fuel line Reducedengine power troubled enginestart Fuel tank is dirty Clean the fuel tank Fuelfilterisclogged Replacethefuelfilter Air filter is dirty Replace the air filter Waterorairint...

Page 28: ...io 50 250 Grill 1200 2300 Baking oven 1000 2000 Fridge 100 150 TV set 100 400 Perforator 600 1400 Drill 400 800 Freezer 100 400 Grinder 300 1100 Circular saw 750 1600 Crank gear 650 2200 Jigsaw 250 70...

Page 29: ...detheunit Iftheproducthasbeenimproperlyinstalledandconnectedtothemainssupplyormisused Iftheclaimedmalfunctioncannotbediagnosedordemonstrated If proper operation of the product can be restored followin...

Page 30: ...___ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________...

Page 31: ......

Page 32: ...Germany ks power de info dimaxgroup de Poland ks power pl info pl dimaxgroup de Ukraine ks power com ua sales ks power com ua CONTACT US...

Reviews: