17
GETTING STARTED
Before starting the engine
make sure that the power rating of tools or power
consumers corresponds to that of the generator. Do not exceed the rated power
of the generator.
Do not connect any devices before the engine start!
Commissioning
In the first 20 operating hours of the generator, the following requirements should
be met:
1. During commissioning, do not connect power consumers, the power of which
exceeds 50% of the rated (operating) power of the device.
2. Be sure to change the oil after the first 20 operating hours. It is better to drain oil
while the engine is still hot after operation to ensure quick and complete oil draining.
Use care when the generator is running:
- You can operate the generator if the voltmeter shows a value of 230 V +/-10% (50
Hz); and a value of 400 V +/-10% (50 Hz) for three-phase generators.
- Monitor the voltmeter and stop the generator if the value is too high.
- Only connect to a DC outlet to charge the battery. When charging batteries, pay
attention to the correct polarity (plus/+ to plus/+, minus/- to minus/-).
- First connect the charger cable to the battery and only then to the generator.
The generator should be connected to the mains supply by a skilled electrician.
Connection errors can cause serious damage to equipment.
- Do not use a voltage of 12 V concurrently with 230 V (400 V for three-phase
generators).
To stop the engine, proceed as follows:
1. Disconnect all the devices connected to the generator, set the circuit breaker to OFF.
2. Allow the generator to operate at idle for 3 minutes so that the alternator cools
down.
3. Set the ignition key to OFF.
4. For models KS 14200HDES ATSR and KS 14200HDES 1/3 ATSR, engines have safety
switches (Fig. 1, no. 9). Use it only in an emergency.
In the power supply mode, the generator should operate no longer
than 30 minutes in the range from rated to maximum power.
Do not change the controller settings in terms of the amount
of fuel or speed governor (this adjustment was made at the
factory). Otherwise, this may result in changes in the engine
operation or its failure. Any modifications in the generator design
deprive the user of the right to warranty service!
IMPORTANT!
ATTENTION - DANGER!
Summary of Contents for KS 14100HDE ATSR