AC PILOT LIGHT (GREEN)

The AC pilot light comes on when the engine starts and produces power.

  

DC PROTECTOR

The DC protector turns to “OFF” automatically when electric device being connected to the generator is operating 

and current above the rated flows. To use this equipment again, turn on DC protector by pressing its button to “ON”.

  FUEL TANK CAP

Remove the fuel tank cap by turning it counterclockwise.

  

FUEL TANK CAP AIR VENT KNOB

The fuel tank cap is provided with an air vent knob to stop fuel flow (for models  KSB 21i S, KS

B 31iE S)

. The air vent 

knob must be turned to “ON”. This will allow fuel to flow to the carburetor and the engine to run. When the engine is 

not in use, turn the air vent knob to “OFF” to stop fuel flow.

  

GROUND (EARTH) TERMINAL

Grounding terminal connects the earth line for prevention of electric shock. When the electric device is grounded, 

the generator must be earthed too.

  

ECONOMY CONTROL SWITCH (ECON)

“ON”

When  the  ECON  switch  is  turned  to  “ON”,  the  economy  control  unit  controls 

the engine speed according to the connected load. As result you get less fuel 

consumption and noise.

“OFF”

When the ECON switch is turned to “OFF”, the engine runs at the rated speed 

(4500r/min) regardless of whether is a load connected or not.

Tip:

The overload indicator light may come on for a few seconds at first

when using electric devices that require a large starting current, 

such as a compressor or a submergible pump. However, this is not 

a malfunction.

IMPORTANT!

Tip:

The ECON must be turned to “OFF” when using electric devices 

that require a large starting current, such as a compressor of a 

submergible pump.

IMPORTANT!

Reduce  the  load  of  the  connected  electric  device  below  the 

specified rated output of the generator if the DC protector turns 

off.  If  the  DC  protector  turns  off  again,  stop  using  the  device 

immediately  and  contact  the  point  of  sale  and  contact  your 

nearest K&S Basic TM Service Center.

IMPORTANT!

When the overload indicator light comes on and power generation stops, proceed as follows:
1. Turn off any connected electric devices and stop the engine.

2. Reduce the total wattage of connected appliance into the rated output.

3. Check for blockages in the cooling air inlet and around the control unit. If any blockages are found, remove.

4. After checking, restart the engine.

www.ks-power.de/en

   

|

    21

Summary of Contents for KSB 21i

Page 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KSB 21i S KSB 21i KSB 35i KSB 31iE S EN ...

Page 2: ...nerator on a flat hard surface away from flammable liquids gases at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We care about the environment therefore we consider it expedient to savepaper and leave in print a short description of the most important sections Failure to follow the recommendations marked with this sign ma...

Page 3: ...nder volume cm3 79 5 119 212 149 8 Engine type gasoline 4 stroke cycle engine Outlets 2х16А Power factor cosφ 1 Fuel tank volume l 4 0 10 13 6 Crankcase volume l 0 4 0 4 0 6 0 8 Engine start ручний manual manual manual electro Noise level LPA 7m LWA dB 68 93 70 95 71 96 69 96 Dimensions L W H mm 535 335 480 455 385 435 520 440 470 585 350 490 Lithium battery Ah 4 5 Net weight kg 20 21 34 30 Protec...

Page 4: ...control switch ECON 7 Grounding 8 Elactrostart for model KSB 31iE S 9 16A outlets MODELS KSB 21i S KSB 31iE S 1 Transport handles 2 Fuel tank cap 3 Control panel 4 Starter 5 Maintenance panel 6 Ventilation grille 7 Silencer MODELS KSB 21i KSB 35i 1 Starter 2 Frame 3 Fuel tank cap 4 Maintenance panel in another side 5 Ventilation grille 6 Silencer 1 Switch 2 Economy control switch ECON 3 Voltage in...

Page 5: ...gine oil is insufficient Add oil and restart IMPORTANT TERMS OF USE 4 When starting operating the generator it s recommended to ground it Before starting the unit remember that the total power of consumers connected should not exceed the rated capacity of the generator TYPES OF CONSUMERS AND INRUSH CURRENT Consumers electrical devices connected to the generator are divided into active and reactive...

Page 6: ...ult you get less fuel consumption and noise OFF When the ECON switch is turned to OFF the engine runs at the rated speed 4500r min regardless of whether is a load connected or not Tip The overload indicator light may come on for a few seconds at first when using electric devices that require a large starting current such as a compressor or a submergible pump However this is not a malfunction IMPOR...

Page 7: ...are higher than standard atmospheric conditions Additionally the load must be reduced when using in a confined area as generator cooling is affected Recommended engine oil SAE 10W 30 SAE 10W 40 Recommended engine oil grade API Service SE type or higher Motor oil quantity see specifications table 1 Unscrew the oil dipstick and wipe it out with a clean cloth 2 Insert the dipstick without screwing it...

Page 8: ... the engine The ECON unit operates in normal mode after the specified period of time while the mode switch is in the ON position When using the generator be careful You can use the generator if the voltmeter shows the value of 230V 10 50 Hz IMPORTANT FUEL TANK VENT For models KSB 21i S KSB 31iE S the fuel tank cap is provided with a vent for sealing the fuel tank The ventilation lever should be us...

Page 9: ...t is on 5 Turn on any electric devices Before operating the generator connect ground wire to ground terminal Please consult with a specialist before using the ground terminal IMPORTANT IMPORTANT Tip Make sure to ground the generator When the electric device is earthed the generator must be grounded too IMPORTANT WARNING Tip The ECON must be turned OFF to increase engine speed to rated rpm If the g...

Page 10: ... DC protector turns off automatically if current above the rated flows during battery charging To restart charging the battery turn the DC protector on by pressing its button to ON If the DC protector turns off again stop charging the battery immediately and contact the point of sale Never smoke or interrupt battery connections to the generator while the battery is being charged Sparks can cause b...

Page 11: ... every 25 operating hours If the engine is often running in dusty or other harsh conditions please clean the air filter every 10 hours If you missed the maintenance time perform it as soon as possible to save the generator engine Stop the engine before servicing Place the generator on a flat surface and remove the spark plug cap to prevent starting the engine Do not run the engine in a poorly vent...

Page 12: ...mmediately after stopping the engine The oil is hot and should be handled with care to avoid burns ATTENTION DANGER Do not tilt the generator while adding oil to the engine This can lead to overfilling and damage to the engine ATTENTION DANGER fill to here It is necessary to check the air filter from time to time and clean any contaminations Regular air filter maintenance is necessary to maintain ...

Page 13: ...void touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair MUFFLER SCREEN AND SPARK ARRESTER TECHNICAL MAINTENANCE 13 1 Remove the screws and then pull outward on the areas of the cover 2 Loosentheboltandremovethemufflercap themufflerscreenandsparkarrester 3 Clean the carbon deposits on the muffler screen and spark arrester usin...

Page 14: ...pose your feet under the generator To prevent damage to the environment separate generator and battery from ordinary waste and recycle them in the safest way passing a special place for disposal Potential faults and troubleshooting methods as well as average device capacities can be found in thefull version of the manual WARRANTY SERVICE TERMS 18 The international manufacturer warranty is 1 year T...

Page 15: ......

Page 16: ......

Page 17: ...tional Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de Україна ТОВ Техно Трейд КС вул Електротехнічна 47 02222 м Київ Україна www ks power com ua sales ks power com ua Россия ТД Рус Энержи К С 129090 г Москва проспект Мира д 19 стр 1 эт 1 пом 1 комн 6б офис 99В www ks power ru info ks power ru ...

Reviews: