INSTALLATION INSTRUCTIONS

We recommend installation by a specialist workshop. A lifting platform is also useful for attaching contact plates in deep-set entry points.
If you have any technical questions, please contact us at 

[email protected]

SAFETY INFORMATION

• WARNING: HIGH-VOLTAGE! 

High voltage is not harmful to healthy persons. You should, however, avoid contact with the contact plates. This applies in particular to people with heart disease 

or heart pacemakers. 

• WARNING: OVERVOLTAGE PROTECTION! 

Remove the fuse when jump starting, carrying out welding work and for rapid charge. There are particular safety regulations applicable when 

working on electric and hybrid vehicles. Please observe the logbook for the vehicle with regards to this. 

• We can only guarantee the full functioning of the device for vehicles with a 12V battery.
• Always protect the marten repellent device against excessive heat and prevent or eliminate dirt on the contact plates.
• Always comply with the working steps in these installation instructions and the safety information.
• Damage caused by not observing the installation instructions is excluded from any liability.
• Clean the engine compartment and parking space thoroughly before installation in order to avoid turf wars

(we recommend the K&K scent mark remover for the engine compartment, item 000300) (10).

Intended use: 

 The device is used to expel martens and other wild animals from the vehicle engine compartment by electric shock, pulsating light and aggressive, pulsating ultrasound

frequencies. After the marten has triggered a short circuit, the high-voltage function is switched o for a short time in order to give the animal the opportunity to escape.

FUNCTION TEST 

prior to installation

All devices are carefully checked by us multiple times. Please also carry out the following nal checks:
1) Remove 

(A)

 the fuse

 (1)

2) Place the contact plate 

(3)

 at the end of the cable 

(4)

, insert screws into the high-voltage cable and lay on insulated underlay (cardboard, wood)

3) Connect the device to the positive and negative pole/earth of the car battery/vehicle body 

(H)

4) Insert fuse 

(I),

 don’t touch the contact plate 

(3)

 any more

5) LED 

(5+6)

 ashes to indicate it is working. This can take a few minutes and take place at a later time 

(K)

6) High voltage can also be measured using a digital multimeter on the contact plate
7) Pull multi-pin plug

 (7)

 to immediately cut off  the current or remove the fuse

 (A) 

(WARNING! After removal, contact plate will carry approx. 3 minutes of residual current)

8) End of function test

Info: 

Warranty is exclusively for the device. There is no assumption of assembly and disassembly costs! Complete dismantling is rarely required - control unit can be exchanged!

INSTALLATION 

when fuse has been removed

CONTROL UNIT

Mount the control unit 

(2) 

in a place where it cannot overheat (e.g. not directly on the exhaust manifold) 

(B) 

and the ultrasound can radiate as freely as possible in order to avoid

acoustic shadow

 (E)

. Connectors 

(7) 

and fuse holders

 (1) 

should be mounted so they are easily accessible.

Connection to positive pole of the 12V battery or comparable positive and negative pole or earthing point of the vehicle body

 (H)

.

CONTACT PLATES

Raise the contact plates 

(3) 

onto the high-voltage cable

 (4) 

and lay this in a strategic location in the engine compartment. Contact plate positions should be adapted to the conditions of the

engine compartment (secure entry points, routes and bite endangered areas)

 (F)

. The high-voltage cable should not be placed anywhere near hot and/or rotating engine parts 

(B)

. Contact plates

should be mounted at a minimum distance of 10mm to other conductive parts (short-circuit hazard)

 (C) 

and at an angle (water drainage)

 (D)

. The contact plates should be installed so that the

martens can simultaneously touch another conductive part to trigger an electric shock. An earthing mat can be added as support (item 1003). Attach the contact plates with cable ties 

(G)

.

Tightening the screws xes the contact plate, ‘taps’ the high-voltage cable and makes contact. The end of the cable should not protrude from the last contact plate due to a short-circuit hazard.

Please attach the yellow warning sticker ‘Warning high voltage’ (9) so it can be clearly seen in the engine compartment (J)!

INITIAL OPERATION

Re-insert the fuse 

(I)

. If the device has been correctly connected, the control LED for the ultrasound function

 (5)

 and high-voltage function 

(6) 

will start to ash (approx. every 3-12 seconds). Start

may be delayed. This procedure may take a few minutes when operating for the rst time 

(K)

. In this state, do not touch the contact plates. The LEDs for function control can ash at various

distances and at dierent degrees of brightness.

The M4700 is an eective and comprehensive defence solution. It combines ultrasound and high voltage in order to achieve the best possible defensive performance. Despite this, we cannot
guarantee that the martens will be expelled in 100% of all cases.

MORE INFORMATION

If the device does not work, it could be for the following reasons:
1) Operating voltage is not between 11.1V and 13.4V.
     Other voltages are causing the marten-scarer to deactivate.
     Voltage > 13.4V: Deactivation switches on automatically (running engine or connection of the battery to external electricity source)
     Voltage > 11.1V: Deactivation from a battery monitor (not enough battery voltage available)
2) The contact plates are touching other conductive parts (short circuit) 

(C)

.

3) Contacts in the connector

 (7)

 to the basic device have no connection (not correctly inserted, pin is bent).

4) Fuse is not in the fuse holder or is faulty 

(1)

.

5) There is a delay of several seconds when switching on. Have patience

 (K)

!

Disposal: 

The device may not be disposed of in household waste.

Please contact your local authority for the correct disposal method.

Accessories

- Extension Kit with 4 additional high voltage contact plates No M4700-KIT
- Replacement control unit No M4700-ST
- Bonnet switch for immediate discharge No 1001

 (a)

- Earthing mat No 1003

TECHNICAL DATA

• Operating voltage: 12 V car battery
• Average power consumption: < 7 mA (± 20%),
• Fitted reverse polarity protection
• Battery monitor: switches o automatically

when battery voltage < 11.1 V (± 3%).

• Ultrasonic frequency: approx. 22.5 kHz (± 10%)

varies randomly in fre rhythm

• Sound pressure: approx. 115 dB (± 25%)
• Fully-encapsulated loudspeaker dome with circular 360° sound radiation
• Output voltage: approx. 250....300 V
• Temperature range: approx. -25...+80 degrees C
• 2 ashing LEDs (for scaring and function control)
• Dimensions of control device: approx. 86 x 55 x 50 mm
• Cable length of high voltage cable: approx. 4 m (± 10%)
• 6 sliding cross-shaped stainless-steel contact pads
• Mini 1 A (or 2 A) blade-type fuse
• Also suitable for vehicles with CAN bus
• Impulse withstand voltage: approx. 40 V 2 mSec

Automatic reduction of power consumption in the case of short-circuit or
contamination (reactive currents) at the high-voltage brushes. Compact
plug-and-socket connection at control device for simple disconnection of
the control device from the cable installation.

 Licensed with the E1

symbol by the German Federal Motor Transport Authority.

EN

Summary of Contents for M4700

Page 1: ...LE PLAQUES HAUTETENSION ULTRASONS SINUSO DAUX 360 TANCHE L EAU 2 0 SUPPORTS DE CONTACTS COULISSANTS EXTENSIBLES Odpuzovac kun Vodotesn kombinovan zar zen Spojuje ultrazvuk a vysok napet Flexibilne se...

Page 2: ...sion Cable ties Attaches de c ble Warning sticker Autocollant d avertissement Scent mark remover 1 8 14x 7 4 3 6x 6 5 2 A 1 1 A 2 A B 2 3 min 10 cm max 85 C E max 2 4 2 3 4 J K 9 B DE EN FR PL IT CZ N...

Page 3: ...ef hrdete Stellen absichern F Das Hochspannungskabel sollte nicht direkt an hei en und drehenden Motorteilen vorbeigef hrt werden B Kontaktplatten sollten mit mindestens 10 mm Abstand zu anderen leite...

Page 4: ...ite endangered areas F The high voltage cable should not be placed anywhere near hot and or rotating engine parts B Contact plates should be mounted at a minimum distance of 10mm to other conductive p...

Page 5: ...iser les lieux d entr e axes de passage et lieux expos s des risques de morsure F Le c ble haute tension ne doit pas tre pass directement sur des pi ces de moteur tr s chaudes et rotatives B Les plaqu...

Page 6: ...wek i miejsca narazone na ataki gryzoni F Kabla wysokiego napiecia nie nalezy prowadzic bezposrednio przy goracych i obracajacych sie czesciach silnika B P ytki kontaktowe powinny miec co najmniej 10...

Page 7: ...uate alle condizioni del vano motore mettere i sicurezza i punti di accesso i passaggi e i punti a rischio morsi F Il cavo di alta tensione non deve esser fatto passare direttamente in parti del motor...

Page 8: ...prostoru motoru zabezpecte jimi m sta vstupu chodbicky a m sta kde hroz prokousnut F Vysokonapetov kabel byste nemeli v st pr mo kolem hork ch a rotuj c ch c st motoru B Kontaktn desky byste meli nam...

Page 9: ...ijke plekken F De hoogspanningskabel moet niet direct langs hete en draaiende motordelen worden gelegd B Contactplaten moeten met minimaal 10 mm afstand tot andere geleidende delen gevaar voor kortslu...

Page 10: ...rois essuppl mentairesNoM4700 KIT Appareildecontr lederemplacementNoM4700 ST D tecteurd ouvertureducapotavecd chargementimm diatNo1001 TapisdemasseNo1003 Akcesoria Zestawakcesori wdorozszerzeniao4styk...

Reviews: