Installation, commissioning and testing quick guide I Jan 1, 2023 | version 1.0 P12
15.6
P
ROGRAMMING STEPS
1.
Open the NCP
2.
At the back of the NCP you will see the programming dipswitches PDS
3.
These are numbered 1 to 8
15.7
R
ECOMMENDED SETTING FOR MARINE APPLICATION WITH MANUAL RELEASE ONLY
1.
Front NCP manual release ONLY, fire detectors are not in use (PDS 1 OFF)
2.
The vehicle mode is disabled is not in use (PDS 2 OFF
3.
Activation of electrical igniters for aerosol fire extinguishers (PDS 3 OFF)
4.
Dual zone alarm is not in use (PDS 4 OFF)
5.
VFC relay meant for ventilation off, activate at 1st (PDS 5 ON)
6.
Extinguishant release 20 seconds (PDS 6 ON - PDS 7 OFF - PDS 8 OFF)
15.8
C
HANGE THE DELAY TIME FROM
20
TO
30
SECONDS
1 Change PDS 7 and 8 to ON position