MULTICAL® 403
9 Communication modules
MULTICAL® 403 can be extended by a wide range of extra functions by means of communication
modules. Below, pulse inputs/outputs and module types are briefly described.
Note:
Before replacing or mounting modules, the supply to the meter must be switched off. The
same applies for mounting of an antenna.
9.1 Module overview
MULTICAL® 403 communication modules:
Type No.
Description
HC-003-10
Data Pulse, inputs (In-A, In-B)
HC-003-11
Data Pulse, outputs (Out-C, Out-D)
HC-003-20
Wired M-Bus, inputs (In-A, In-B)
HC-003-21
Wired M-Bus, outputs (Out-C, Out-D)
HC-003-22
Wired M-Bus, Thermal Disconnect
"#%
HC-003-30
Wireless M-Bus, inputs (In-A, In-B), 868 MHz
HC-003-31
Wireless M-Bus, outputs (Out-C, Out-D), 868 MHz
HC-003-40
Analog outputs 2 x 0/4…20 mA
"#
HC-003-43
PQT Controller
"#
HC-003-50
Low Power Radio, inputs (In-A, In-B), 434 MHz
%
HC-003-51
Low Power Radio GDPR, inputs (In-A, In-B), 434 MHz
%
HC-003-66
BACnet MS/TP, inputs (In-A, In-B)
"
HC-003-67
Modbus RTU, inputs (In-A, In-B)
"
"
The module requires that the meter is mains-supplied.
#
The module requires an external power supply.
%
The module requires a specific configuration in the meter, see the module data sheet for
details.
9.2 Pulse inputs
Pulse inputs A and B are used for connection of
extra meters with either Reed-switch output or
passive electronic pulse output.
Min. pulse duration is 30 ms. and max pulse
frequency is 3 Hz.
65 +
Pulse input A
66 -
67 +
Pulse input B
68 -
If a module with pulse inputs is mounted in MULTICAL®, the meter is automatically configured for
pulse inputs. Note that the meter factor (litres/pulse) must match the extra water meters and the
configurations of inputs A and B. After delivery, the configurations of pulse inputs A and B can be
changed by means of the PC program METERTOOL HCW.