MULTICAL® 403
9.4 Data + pulse inputs, type HC-003-10
The data terminals are used for connection of
e.g. a PC. The signal is passive and galvanically
separated by means of optocouplers.
Conversion to RS232 level requires connection
of data cable 66-99-106 (D-SUB 9F) or
66-99-098 (USB type A) with the following
connections:
62
Brown
(DAT)
63
White
(REQ)
64
Green
(GND)
9.5 Data + pulse outputs, type HC-003-11
The data terminals are used for connection of
e.g. a PC. The signal is passive and galvanically
separated by means of optocouplers.
Conversion to RS232 level requires connection
of data cable 66-99-106 (D-SUB 9F) or
66-99-098 (USB type A) with the following
connections:
62
Brown
(DAT)
63
White
(REQ)
64
Green
(GND)
9.6 M-Bus + pulse inputs, type HC-003-20
M-Bus module with primary, secondary and
enhanced secondary addressing.
The module is connected to an M-Bus master
via terminals 24 and 25 using a twisted pair.
The polarity is without importance for the
functionality.
The module is powered by the connected
master.