Kamstrup flowIQ 4200 Installation Manual Download Page 14

14

Kamstrup A/S • 55123307_A1_EN-US_06.2022

Installation guide flowIQ® 4200

6  ICES/ISED cautions

English:

This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause 
undesired operation of the device.
Complies with the Canadian ICES-003 Class B specifications.
This device complies with RSS 247 of Industry Canada. This Class B device meets all the 
requirements of the Canadian interference-causing equipment regulations.
This radio transmitter IC ID 22376-KWM4220 has been approved by Innovation, Science 
and Economic Development Canada to operate with the antenna types listed below, with 
the maximum permissible gain indicated. Antenna types not included in this list that 
have a gain greater than the maximum gain indicated for any type listed are strictly 
prohibited for use with this device.

This equipment has been approved for fixed operation, and unless otherwise advised 
in separate supplemental instructions for individual wireless transmitter(s), requires 
minimum 25 cm spacing be provided between antenna(s) and all person’s body 
(excluding extremities of hands, wrist and feet) during wireless modes of operation.

Maximum gain:

Antenna type

450-470 MHz:

902-928 MHz:

Helix

-2.9 dBi

-2.1 dBi

PIt, small

-5.3 dBi

1.2 dBi

Wall

0.5 dBi

-1.6 dBi

Must be installed to provide a separation distance of at least 25 cm from all persons.

Summary of Contents for flowIQ 4200

Page 1: ...Installation guide flowIQ 4200 US Kamstrup Water Metering LLC 245 Hembree Park Drive Ste 110 Roswell GA 30076 USA info us kamstrup com...

Page 2: ...installation 6 4 1 Sediments in the water 7 4 2 Spool piece installation only applies to 6 and 8 meters 7 4 3 Split flange installation 8 4 3 1 General flange features and specifications 9 4 3 2 Criss...

Page 3: ...the correct flow direction Ensure correct operating pressure Avoid placing the meter in direct sunlight For meters subjected to any kind of mechanical impact it is recommended to install a lid on the...

Page 4: ...e mechanical impact For flowIQ 4200 meters it is possible to install a lid The lid can be ordered as a separate accessory and will not be attached or mounted on the meter from factory Lid type no 66 9...

Page 5: ...2 Installation precautions The sealing surface of the flanged connection must be clean and level Replace gaskets when installing a new water meter ALWAYS use new gaskets Gaskets in original quality i...

Page 6: ...er detects reverse flow The meter calculates the volume in a separate register not verified for billing Reverse volume is NOT displayed on the meter 4 flowIQ 4200 installation A flowIQ 4200 meter is d...

Page 7: ...ts to install the meter with the cup facing upwards 4 2 Spool piece installation only applies to 6 and 8 meters Spool pieces should be mounted on the pipeline flanges first to ensure flexible options...

Page 8: ...ce depends on the installation scenarios and the space conditions Both options are described below and both installation options require the same procedure for tightening the flange bolts in the descr...

Page 9: ...parts during installation Pushing nut milling If extra space for the gasket is needed insert a 7 16 nut in the pushing nut milling and insert a 7 16 bolt from the opposite side to press and enlarge th...

Page 10: ...s below 4 3 3 Installing the split flanges on the meter first Place the meter vertically on one end Fixate the two split flanges together by using a bolt Place the flange around the meter and close th...

Page 11: ...lts and nuts Tighten the bolts in the described criss cross pattern and with the correct tightening torque mentioned in the table Repeat the sequence three times to ensure that all bolts are tightened...

Page 12: ...inlets are advisable This applies to all flange meters 4 6 Flow disturbance and flow cavitation The components mentioned below can generate heavy flow disruptions or pressure drops Butterfly valve Pr...

Page 13: ...suant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate ra...

Page 14: ...been approved by Innovation Science and Economic Development Canada to operate with the antenna types listed below with the maximum permissible gain indicated Antenna types not included in this list t...

Page 15: ...riel brouilleur du Canada Cet metteur radio IC ID 22376 KWM4220 a t approuv par Innovation Sciences et D veloppement conomique Canada pour fonctionner avec les types d antenne num r s cidessous avec l...

Page 16: ...16 Kamstrup A S 55123307_A1_EN US_06 2022 Installation guide flowIQ 4200...