Installation guide flowIQ® 4200

5  FCC Cautions

Caution: 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the users authority to operate the equipment.

RF Exposure compliance statement: 

This device may be used with no restrictions, since 

the source-based time-averaged output power is ≤ 60/f(GHz) mW.

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:

This device may not cause harmful interference, and

This device must accept any interference recieved, including interference that may 
cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. 
However, there is no guarantee that interference will not occur in a particular installation. 
If this equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures:

 

- Reorient or relocate the receiving antenna.

 

- Increase the separation between the equipment and receiver. 

 

- Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected. 

 

- Consult the dealer or an experienced radio/TV technician for help.

Summary of Contents for flowIQ 4200

Page 1: ...Installation guide flowIQ 4200 US Kamstrup Water Metering LLC 245 Hembree Park Drive Ste 110 Roswell GA 30076 USA info us kamstrup com...

Page 2: ...installation 6 4 1 Sediments in the water 7 4 2 Spool piece installation only applies to 6 and 8 meters 7 4 3 Split flange installation 8 4 3 1 General flange features and specifications 9 4 3 2 Criss...

Page 3: ...the correct flow direction Ensure correct operating pressure Avoid placing the meter in direct sunlight For meters subjected to any kind of mechanical impact it is recommended to install a lid on the...

Page 4: ...e mechanical impact For flowIQ 4200 meters it is possible to install a lid The lid can be ordered as a separate accessory and will not be attached or mounted on the meter from factory Lid type no 66 9...

Page 5: ...2 Installation precautions The sealing surface of the flanged connection must be clean and level Replace gaskets when installing a new water meter ALWAYS use new gaskets Gaskets in original quality i...

Page 6: ...er detects reverse flow The meter calculates the volume in a separate register not verified for billing Reverse volume is NOT displayed on the meter 4 flowIQ 4200 installation A flowIQ 4200 meter is d...

Page 7: ...ts to install the meter with the cup facing upwards 4 2 Spool piece installation only applies to 6 and 8 meters Spool pieces should be mounted on the pipeline flanges first to ensure flexible options...

Page 8: ...ce depends on the installation scenarios and the space conditions Both options are described below and both installation options require the same procedure for tightening the flange bolts in the descr...

Page 9: ...parts during installation Pushing nut milling If extra space for the gasket is needed insert a 7 16 nut in the pushing nut milling and insert a 7 16 bolt from the opposite side to press and enlarge th...

Page 10: ...s below 4 3 3 Installing the split flanges on the meter first Place the meter vertically on one end Fixate the two split flanges together by using a bolt Place the flange around the meter and close th...

Page 11: ...lts and nuts Tighten the bolts in the described criss cross pattern and with the correct tightening torque mentioned in the table Repeat the sequence three times to ensure that all bolts are tightened...

Page 12: ...inlets are advisable This applies to all flange meters 4 6 Flow disturbance and flow cavitation The components mentioned below can generate heavy flow disruptions or pressure drops Butterfly valve Pr...

Page 13: ...suant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate ra...

Page 14: ...been approved by Innovation Science and Economic Development Canada to operate with the antenna types listed below with the maximum permissible gain indicated Antenna types not included in this list t...

Page 15: ...riel brouilleur du Canada Cet metteur radio IC ID 22376 KWM4220 a t approuv par Innovation Sciences et D veloppement conomique Canada pour fonctionner avec les types d antenne num r s cidessous avec l...

Page 16: ...16 Kamstrup A S 55123307_A1_EN US_06 2022 Installation guide flowIQ 4200...

Reviews: