TECHNICAL DESCRIPTION flowIQ® 3100
42
Kamstrup
A/S • Technical Description •
5512-1242_N
1_GB •
10.2019
Below you see an example of volume reading in normal mode showing V1 = 03,745.214 m
3
Below you see an example of volume reading in verification mode showing V1HighRes = 45,214.698 L
16.11.2
Resolution
The resolution of the display can be varied by changing the number of visible decimals after the point. This change
has no influence on the measurement itself. The five digits before the point are always on. The number of decimals
after the point can be selected by the customer at 0, 1, 2 or 3 decimals when submitting the order, and later with
METERTOOL. If no selection is made, the default value of three decimals after the point will be used. If the
resolution is set at 0, 1 or 2 decimals, the last digit/digits will be removed without round-off.
16.11.3
Dots (flashing squares)
The two dots (framed in thesketch below) indicate that the meter is active. They are alternately ON at a frequency
determined by the meter's mode. In normal mode they flash once a second. In verification mode they flash twice
a second.
Below you see the shift between the two dots: