TECHNICAL DESCRIPTION flowIQ® 3100
18
Kamstrup
A/S • Technical Description •
5512-1242_N
1_GB •
10.2019
Data
Explanation
Serial number
The meter’s serial number. The serial number will never be encrypted.
Meter specific data
Identification as cold water meter
Kamstrup's specific Wireless M-Bus producer-ID
Information on length and format of data package
Information on encryption of data package
Meter reading
The current meter reading from the meter's legal register
Target volume
Meter reading of the 1
st
of the month
Meter reading of the first
day of the year
Max flow**
Maximum flow, which has been measured during the year, month or day
depending on the selected R- Package
Min. flow
Minimum flow, which has been measured during the year, month or day
depending on the selected R- Package
Water temperature*
Minimum, max or average water temperature for the last completed year,
month or day
–
depending on the choice of the 'R-package'
Meter temperature
Minimum, maximum or average ambient/meter temperature, latest year,
month or day
–
depending on choice of ’R’
- value
Info codes
Info codes which are active at present
Historical info codes
Info codes which have been active within the latest 30 days including
information on how long they have been active
–
on a scale of 1-7
Reverse volume
The V1 reverse register. Registration of volume of the water running in the
wrong direction.
Target date
Date of target volume storage in the monthly log. The date is the last day of
the month
–
i.e. a monthly log created at midnight the night before d.
1/8/2012, will have target date 31/7 2012.
Date/time stamp
Time and date for reading
Battery left
Indicates battery capacity
–
how many days approx. are left
Radio Disabled
Only module 99 and 98
*
Measuring the water temperature is only valid for meter sizes 1.6, 2.5 and 4.0 m
3
/h
**
‘M
ax flo
w’
is from meter size:
1.6 - 16 m³/h always in l/h
25-100 m³/ h, the flow is indicated in m³/h (2 decimals) - from this SW revision and forward:
SW rev.: T1 (wireless M-bus),
G1(wired M-bus)
1.6 - 63 m³/h
–
Sigfox always in l/h
Module 46: If encryption has been selected, when submitting the order, all variable data will be encrypted
with
‘
128 bits AES counter mode
’
encryption.
Kamstrup A/S recommends encryption.