flowIQ® 3100 TECHNICAL DESCRIPTION
Kamstrup
A/S • Technical Description • 5512
-1242_N1
_GB •
10.2019
19
7.2
Wired M-Bus version of flowIQ® 3100
Note!
flowIQ®3100 with wired M-Bus
–
only available up to and including DN80 (40 m
3
) type: C0N
7.2.1
For billing and analysis
•
Fixed datagram
•
Up to 9600 baud communication speed
•
Primary/secondary/enhanced secondary addressing
•
According to M-Bus standard EN 13757:2013
7.2.2
Introduction
flowIQ® 3100 is available with wired M-Bus offering easy reading of the water meter via, for example, an M-Bus
Master. Also electricity meters or heat/cool meter with a built-in M-Bus micro-master can be used.
The M-Bus interface fulfills the requirements in the M-Bus standard EN 13757:2013 and can be used in a wide
variety of applications using M-Bus protocol.
7.2.3
Applications
The M-Bus meter is designed with focus on high flexibility, to fulfill a wide pallet of applications.
7.2.4
Analysis
flowIQ® 3100 supports high quantities of data in a fixed datagram. This is valid for both actual meter data as well
as for historical logger data.
7.2.5
Billing
All relevant data for billing purposes can be read out from flowIQ® 3100.
7.2.6
M-Bus Addressing
The M-Bus interface supports primary, secondary and enhanced secondary addressing.
7.2.7
Primary addressing
–
(000-250)
When nothing else is specified, the M-Bus interface will automatically use the last 2-3 digits of the flowIQ® 3100
serial number as the primary address.
During the order process or by use of the METERTOOL HCW programming software, dedicated primary addresses
can be selected. Further on, the primary address can be changed over the M-Bus network using standardized M-
Bus commands.
7.2.8
Secondary addressing
–
(M-Bus ID No. 00000000-99999999)
The last eight digits of the serial number are used as M-Bus ID number for secondary addressing.
7.2.9
Enhanced Secondary addressing
–
(M-Bus ID No. 00000000-99999999)/( M-Bus fabrication No. 00000000-99999999)
Enhanced secondary addressing is supported by adding the meter’s serial number as M
-Bus Fabrication Number
to the secondary address.
7.2.10
Installation
The meter is delivered with a 1.5 meter long standard polarity independent connection.