TECHNICAL DESCRIPTION
Kamstrup 162M/382M
5512-1040 GB/05.2012/Rev. C1
57
10.2.2
Configuration 2 ( FFF-GG-HH-I )
FFF
Display configuration
GG
Target date
HH
Debiting logger interval
I
Pulse output lenght / alarm input on module port
For creating display configuration (FFF), complete document no. 5811-549 GB, see
10.7 Display configuration
. For
information about optional display configurations, please contact Kamstrup A/S.
The below table gives examples of released display readings.
GG
Target date
GG
HH
I
Controlled externally
00
1.
01
2.
02
3.
03
:
:
:
:
:
:
27
27
28
28
HH
Debiting logger interval
None (controlled externally)
00
Monthly
01
Every second month, January
02
Every second month, February
03
Every third month, January
04
Every third month, February
05
Every third month, March
06
Half-yearly, January
07
Half-yearly, February
08
Half-yearly, March
09
Half-yearly, April
10
Half-yearly, May
11
Half-yearly, June
12
Yearly, January
13
Yearly, February
14
Yearly, March
15
Yearly, April
16
Yearly, May
17
Yearly, June
18
Yearly, July
19
Yearly, August
20
Yearly, September
21
Yearly, October
22
Yearly, November
23
Yearly, December
24
I Pulse output lenght / alarm input on module port
I
30 msecs. pulse length / no alarm input
1
30 msecs. pulse length / alarm input
2
80 msecs. pulse length / no alarm input
3
80 msecs. pulse length / alarm input
4