2. Safety Information

Installation,  assembly  and  maintenance  work  on  electrical  units  should
only be performed by a qualified electrician in compliance with the VDE
guidelines. Wiring should comply with the applicable VDE regulations and
provisions laid down by the regional electricity providers. Non-compliance
with  the  regulations  and  operating  instructions  may  result  in  the  units
malfunctioning  with  consequential  damage  and  danger  to  people.  The
units  may  be  incorrectly  wired  by  the  wires  being  swapped  –  danger
of fatal injury! Disconnect all parts of the system from the mains power
supply  and  prevent  them  from  being  reconnected  before  starting  any
connection and maintenance work! The unit should only be connected to
fixed cabling.
Please read these instructions in full to guarantee a correct installation.

Please note the following safety-relevant information:

• Disconnect all parts of the system that are being worked on.
• Ensure that the system cannot be accidentally re-connected!
• Caution! Pipes, casings and fittings may become very hot depending on

the operating mode!

• Qualified personnel must have undergone training to provide them with

adequate knowledge of the following:

• Safety and accident prevention regulations
• Guidelines and recognised technical regulations, i.e. VDE (Association of

German Electricians) regulations

• DIN and EN standards
• Accident prevention regulations VBG, VBG4, VBG9a
• DIN VDE 0100, DIN VDE 0105
• EN 60730 (Part 1)
• Technical wiring regulations issued by the regional electricity providers

Modifications to the unit

Do not undertake any modifications, refurbishments or upgrades on the
Katherm NX unit without discussing these with the manufacturer as these
may  impair  the  safety  and  operation  of  the  unit.  Do  not  carry  out  any
action  on  the  unit  that  is  not  described  in  these  instructions.  On-site
systems  and  cabling  must  be  suitable  for  connection  to  the  intended
system!

The floor duct has openings provided for the installation of
a potential compensation line.

3. Models/Scope of Delivery

Floor ducts are delivered as standard with the following (see Fig. 2):

l

Height-adjustment  feet,  room-side,

1

Rubber  underlays  for  sound

absorption 

2

; screws and rawlplugs, provided on-site;

l

raised floor mounting feet with sound absorption 

3

3.45

Ka

therm

NX - 

Natural Convection

Safety Information

Summary of Contents for Katherm NX

Page 1: ...59 04 14 1 GB I Sap Nummer 1146161 Katherm NX 3 45 Trench Heating with natural convection Installation instructions Keep these instructions in a safe place for future use Kampmann de installation_manuals ...

Page 2: ... Danger Non compliance with this information may lead to serious personal injuries or damage to property Danger of electric shock Non compliance with this information may lead to serious personal injuries or damage to property from an electric current Carefully read these instructions in full prior to any assembly and installation work Anyone involved in the installation commissioning and use of t...

Page 3: ... proper use is deemed to include observing the installation information described in these instructions The installation of this product requires specialist knowledge of heating cooling ventilation and electrical engineering This knowledge generally learned in vocational training in the fields mentioned in section 2 is not described separately Errors with the connection or modifications may lead t...

Page 4: ...g on the operating mode Qualified personnel must have undergone training to provide them with adequate knowledge of the following Safety and accident prevention regulations Guidelines and recognised technical regulations i e VDE Association of German Electricians regulations DIN and EN standards Accident prevention regulations VBG VBG4 VBG9a DIN VDE 0100 DIN VDE 0105 EN 60730 Part 1 Technical wiri...

Page 5: ...h screws and rawlplugs provided on site l Use the pipe opening cut out on the room side for the water side connection Remove the pipe conduit that has been cut out Seal the thermostatic valve and return shut off valve with appropriate sealing compound and screw the valves to the fan connections on the convector l Then fit the flow and return pipes l Run a pressure test l Attach these installation ...

Page 6: ... Dimensions Height Adjustment Separately packaged roll up grilles e g when using installation covers to protect from dirt are pre rolled in the factory If the steel spiral springs are stretched this may result in the grille appearing over long Unroll and lay out the grille for a few hours to return it to its original length The frame is easier to fit if the roll up grille is inserted with an up an...

Page 7: ...moelectric actuator type 194000146905 5Return shut off valve straight type 194000145952 6Unit shown with roll up grille 7Pipe conduits cut out 8Cable conduits Katherm NX Natural Convection 3 45 Water Connection Pipe Conduits 4 3 1 6 8 7 5 2 6 8 7 Connection side left Connection side right All dimensions in mm Katherm NX 130 A B C D Duct height 92 mm 63 43 92 42 Duct height 120 mm 91 71 120 70 ...

Page 8: ...its cut out 8Cable conduits Duct height 150 200 mm 1Flow 2Return 3Valve body straight 1 2 type 194000146909 or type 194000346909 presettable 4Thermoelectric actuator type 194000146905 5Return shut off valve straight type 194000145952 6Unit shown with roll up grille 7Pipe conduits cut out 8Cable conduits 4 3 1 8 7 4 5 3 12 6 8 7 2 5 6 All dimensions in mm All dimensions in mm Katherm NX 175 A B C D...

Page 9: ...duits cut out 8Cable conduits Duct height 150 200 mm 1Flow 2Return 3Valve body straight 1 2 type 194000146909 or type 194000346909 presettable 4Thermoelectric actuator type 194000146905 5Return shut off valve straight type 194000145952 6Unit shown with roll up grille 7Pipe conduits cut out 8Cable conduits 4 3 1 6 8 7 4 5 3 12 6 8 7 2 5 All dimensions in mm All dimensions in mm Katherm NX 225 A B C...

Page 10: ...gular maintenance and inspections are required in order to permanently guarantee the function and performance of the Katherm NX Heat exchanger l Inspect the integral heat exchanger every six months for dirt and possible damage A visual inspection is sufficient here l Carefully vacuum the heat exchanger if dirty Valves l Inspect the valves as well every 12 months and check the leak tightness visual...

Page 11: ...ly 3 x 1 5 Mains power supply 3 x 1 5 Mains power supply 3 x 1 5 Mains power supply 3 x 1 5 3 x 1 5 3 x 1 5 3 x 1 5 3 x 1 5 Clock thermostat flush mounted type 194000146933 3 x 1 5 to further thermoelectric actuators type 194000146905 total max 10 The number of connecting wires required with cable diameters e g 3 x 1 5 incl fuses is given on the individual control units Flush mounted box provided ...

Page 12: ...traight type 194000146909 or type 194000346909 presettable Return shut off valve straight type 194000145952 Return shut off valve straight type 194000145952 Valve straight type 194000146909 or type 194000346909 presettable Valve straight type 194000146909 or type 194000346909 presettable Return shut off valve straight type 194000145952 Return shut off valve straight type 194000145952 Flow 1 2 conn...

Page 13: ...13 Katherm NX Natural Convection 3 45 Notes ...

Page 14: ...14 3 45 Katherm NX Natural Convection Notes ...

Page 15: ...15 Katherm NX Natural Convection 3 45 Notes ...

Page 16: ...rt Str 128 130 49811 Lingen Ems Germany T 49 591 7108 0 F 49 591 7108 300 E info kampmann de Kampmann UK Ltd Dial House Govett Avenue Shepperton Middlesex TW17 8AG Great Britain T 44 0 1932 228592 F 44 0 1932 228949 E info kampmann uk co uk ...

Reviews: