Troubleshooting / Storage
If you can not solve the trouble according to one of the mentioned solutions, please contact
us via our website: www.kettler.co.uk or contact your dealer or Distributor.
Storage
• Turn control knob to “OFF” position (full disk).
• Turn LPG cylinder to “OFF” position.
• Store the appliance in a cool dry place away from direct sunlight; store it upright in an area
sheltered from direct contact with inclement weather (such as rain, sleet, hail, snow, dust and
debris). If desired, cover to protect exterior surfaces and to prevent build up in air passages.
• During periods of extended inactivity or when transporting: ensure the control knob is turned
to the “off” position. Disconnect LPG cylinder and move to a secure, well ventilated location
outdoors. DO NOT store above 50 °C.
•
Note: Ensure the appliance is cool before covering.
Problem:
Condition:
Solution suggested:
Carbon build-up
Dirty or film on burner.
Clean burner.
Flash back (flame
inside burner)
Burner ports are blocked.
Switch OFF the appliance. Close LPG cylinder
valve. Wait 2 minutes, following the ignition
procedure. Ignite burner. If problem continuous,
switch-off. Contact your dealer
Thick black smoke
Blockage in the burner.
Turn control knob to “OFF” position, let the
appliance to cool at room temperature and
remove blockage and clean burner inside and
outside.