74
GB
Preliminary checks
Before switching on the pellet boiler, make sure that the pellet hopper is full, the combustion chamber is clean, the glass
door is closed, the power supply plug is connected and the switch on the back is set to “1.”
TURNED OFF
The boiler is off.
TURNED ON
The stove is in the first ignition phase.
The glow plug and fume extractor are active.
LOAD PELLET
In this phase of the ignition process the stove starts loading the pellets into the brazier.
The glow plug, the fume extractor and the cochlea engine are active.
FIRE PRESENT
In this phase of the ignition process the stove starts loading the pellets into the brazier.
The fume extractor and the cochlea engine are active.
BRAZIER CLEANING
The stove is cleaning the basket.
The smoke extractor runs at maximum speed and the pellet load is at minimum.
WORK
The stove is working, in this case at power 3.
The detected room temperature is 21 ° C. During normal work, the fumes fan, the auger motor
and the room fan are active.
21 : 10
22°C P-1
TURNED OFF
14 : 35
22°C P-1
FIRE
present
14 : 35
21°C P-2
ACCENDE
14 : 35
21°C P-2
LOAD
pellet
15 : 18
22°C P-3
WORK
15 : 18
22°C p-2
BRAZIER
CLEANING