71
GB
1 =
Valve motorization
2 = NTC5K probe on DHW tank
3 = NTC5K probe on Puffer
Technical w
ater
1
2
3
Scheme 05 :
the boiler is connected to a technical w
ater puffer
.
The boiler is switched off when the upper probe is satisfied.
The boiler is switched on when the inferior probe is not satisfied.
The heating w
ater will then be tak
en from this puffer by means of the pumps and the relays are not controlled by the boiler control unit.
a)
To set the temper
ature in the DHW tank,
press the
k
ey
. Use the
and
k
eys to select the desired degrees
b)
To set the temper
ature in the technical w
ater puffer
, press the
k
ey and use the
and
k
eys to select the desired degrees
c)
To set the work power press the
k
ey and adjust it with the k
eys
and
The restart from the stand-by state occurs automatically when the temper
ature detected by the lower puffer probe is lower than the set temper
ature (b)
the scheme is indicative and w
ants to demonstr
ate
only the components that can be managed by
the boiler
. Any relay pumps must be controlled
separ
ately from the boiler