KALE FANS Eurus D6BAA49 Quick Installation Manual Download Page 10

INSTALLATION GUIDE

KALE FANS

www.kalefans.net

INSTALLATION GUIDE

EURUS  

-16-

-15-

12

Install I-type fan blade retainer 

 

Unbolt the pre-tightened fasteners on fan blade next to hub, connect fan blade retainer one by one with 

17# open end wrench(i), speed wrench(f) and 16# socket wrench.

Please note that slotted hole is underneath and round hole is on top.

spring washer

round hole is on top.

slotted hole is underneath

flat washer

pre-tightened fasteners

pre-tightened fasteners

13

Install Hub Cover

 

Tighten 5 pcs M5X12mm fasteners to fix hub cover on the hub with straight screwdriver(m).

M5X12mm fasteners

power output
power input

1.2m-1.3m from the ground to the bottom of the cabinet

14

Install Control Box

 

Fix control box to confirm mounted position, keep the box balanced. Punch holes with electric tools and fix buckles into

the holes with cross screwdriver(l). The box should fixed at a height between 1.2m-1.3m from the ground.

power output

small cooling fan

power input

input lines

output lines

display panel

breaker

15

Wiring for control box

 

Cable from motor connect power output end on controller and power supply connect the input end, and tighten them 

with straight screwdriver(m). Must confirm to connect wires with the same color, output and input ends must not be

connected wrongly, and note the data on the screen.

Option 1: wiring method for power of 380V-480V, 3 phases at site 

R2-1

S2

U

V

W

PE

PE

R2

S2

T2

counter-clockwise direction is forward 

16

Test Run

 

Test run for 15 mins to check whether there is any abnormal sound/noise, any shake of safety guy wire, or the current is 

in rated range.  Also confirm the fan running safely with safety distance from obstacles.

yellow-green(ground lead for input)

yellow-green(ground lead for motor)

blue

red

yellow

yellow-green(ground lead for input)

yellow-green(ground lead for motor)

R1

S1

T1

input lines

output lines

R2-1

S2

U

V

W

PE

PE

R2

S2

blue

red

yellow

R1

S1

cabinet

buckle

display window

lock

switch-on/off
speed controller

7

hub cover

8

Option 2: wiring method for power of 220V-240V, Single phase at site 

clockwise direction is reverse

Summary of Contents for Eurus D6BAA49

Page 1: ...hai Corp Tel 021 57685070 Fax 021 57685025 Web www kalefans net Email sales kalefans com Address No 420 Chundong Rd Minghang Dist Shanghai Ka Le Envir onm ent al T echno l ogy Shangha i Cor p Quick In...

Page 2: ...Tools 8 Installation Condition and Mounting 9 5 1 Installation Condition 9 Troubleshooting 2 0 4 3 8 Preparation Before Installation 5 9 5 2 Common Mounting 6 1 1 Start Installation 7 1 8 Controller P...

Page 3: ...ea which leads to the double function of ventilation and temperature reduction Compared to the traditional HVAC conditioner and small high speed air blower the fan is superior in application and that...

Page 4: ...4 M5x12mm fastener x5pcs 7 hub coverx1pcs 8 cable pipex1roll 9 cablex1roll 10 control box x1set 19 cables clip for beamx8pcs 18 manualx1pcs 20 CDx1pcs 21 fan blade x5pcs 22 extension tube x1pcs 23 st...

Page 5: ...wing motor 1 top plate 2 3 4 5 6 8 11 11 12 14 15 16 16 22 spacer beam clip turnbuckle I type fan blade retainer hub cover steel guy wire for safety steel guy wire steel wire lock M12x60mm fastener M1...

Page 6: ...speed switch Control Box 3 1 Components Drawing 4 Preparation Before Installation 4 1 Preparation for Safety Gears 4 2 Preparation for Installation Tools safety cap a work gloves b safety belt c warni...

Page 7: ...eam bottom Dig holes marked at first with percussion drill the depth of the hole refers to the length of expansion bolt Drive expasion bolts into the holes and then mount fasteners for bending pieces...

Page 8: ...xtension tube between the bending pieces align to the holes with M16X120mm fasteners and pretighten them Adjust the tube vertical with level meter e then tighten fasteners with 24 open end wrench g sp...

Page 9: ...safety wires must be isometric symmetrical and even load At last tighten all wire locks with speed wrench f and 10 socket wrench r and paint with screw glue on locks and turnbuckle force bearing poin...

Page 10: ...cooling fan power input input lines output lines display panel breaker 15 Wiring for control box Cable from motor connect power output end on controller and power supply connect the input end and tigh...

Page 11: ...lines If the fan reverse runs with small air volume please power off correctly and exchange connection of two lines of U red V yellow and W blue to keep forward running 17 Clean the Site Remove all th...

Page 12: ...and potential danger in the fan operation space 2 confirm the input power supply is correct and meet the product s requirement 3 confirm the speed knob at the minimum position 4 turn on the fan turn t...

Page 13: ...charge from output phases to ground 16 Short Circuit X X Short circuit in motor or on motor terminals 17 Control word time out X X No communication to frequency converter 25 Brake resistor short circu...

Page 14: ...ance by customers Failure occurs during the quality guarantee period such as products our company provide free consultation maintenance services including vulnerability free replacement of spare parts...

Reviews: