12
Install I-type fan blade retainer
Unbolt the pre-tightened fasteners on fan blade next to hub, connect fan blade retainer one by one with
17# open end wrench(i), speed wrench(f) and 16# socket wrench.
Please note that slotted hole is underneath and round hole is on top.
spring washer
round hole is on top.
slotted hole is underneath
flat washer
pre-tightened fasteners
pre-tightened fasteners
13
Install Hub Cover
Tighten 5 pcs M5X12mm fasteners to fix hub cover on the hub with straight screwdriver(m).
M5X12mm fasteners
power output
power input
1.2m-1.3m from the ground to the bottom of the cabinet
14
Install Control Box
Fix control box to confirm mounted position, keep the box balanced. Punch holes with electric tools and fix buckles into
the holes with cross screwdriver(l). The box should fixed at a height between 1.2m-1.3m from the ground.
power output
small cooling fan
power input
input lines
output lines
display panel
breaker
15
Wiring for control box
Cable from motor connect power output end on controller and power supply connect the input end, and tighten them
with straight screwdriver(m). Must confirm to connect wires with the same color, output and input ends must not be
connected wrongly, and note the data on the screen.
Option 1: wiring method for power of 380V-480V, 3 phases at site
R2-1
S2
U
V
W
PE
PE
R2
S2
T2
counter-clockwise direction is forward
16
Test Run
Test run for 15 mins to check whether there is any abnormal sound/noise, any shake of safety guy wire, or the current is
in rated range. Also confirm the fan running safely with safety distance from obstacles.
yellow-green(ground lead for input)
yellow-green(ground lead for motor)
blue
red
yellow
yellow-green(ground lead for input)
yellow-green(ground lead for motor)
R1
S1
T1
input lines
output lines
R2-1
S2
U
V
W
PE
PE
R2
S2
blue
red
yellow
R1
S1
cabinet
buckle
display window
lock
switch-on/off
speed controller
7
hub cover
8
Option 2: wiring method for power of 220V-240V, Single phase at site