1.5 b
AtteRy
i
nfoRMAtion
1.0 Getting Started
Keep Batteries at Room Temperature:
That means storing between 32 and 80 degrees F (00C to 270C). The worst thing that can happen to a lithi
-
um-ion Battery is to have it exposed to elevated temperatures.
Batteries Lose Capacity Over Time:
Batteries naturally deteriorate over time whether being used or not. Batteries deteriorate at a rate of 10% run
time per year.
Fully Discharge vs. Partial Discharge and the Effect on Battery Cycles:
Unlike lead acid batteries typically used in auto scrubber, the Kaivac Battery
is not damaged by fully discharging. The BMS (Battery Management System) has a cutoff voltage of 30V which protects the Battery from experi
-
encing full discharge. Running the Battery to full discharge will reduce the amount of charge cycles. The expected hours of use are approximately
600 hours. For example, if running to full discharge, you would expect 400 cycles. If you run to 80% discharge, then you would expect to get more
cycles (500 cycles).
Extended Storage:
It is recommended to discharge to 40% capacity (35V) and store in a cool location (between 320F to 800F or 00C to 270C).
Hour
Battery Gauge:
The Kaivac Batteries come with a built-in Battery Gauge or “Fuel Gauge” which shows the approximate run time remaining.
Disposal:
Properly dispose of Battery at a local recycling location.
Battery Specifications
Weight
With Box, 11 lbs. (4,9 kg)
Body Material
Injection Mold Polypropylene
Dimensions (H x W x D)
18 x 7 x 5 in. (45,7 x 17,8 x 12,7 cm)
Voltage
36V DC
Battery Capacity
15 A-hr
Battery Current
15 A DC
Battery Type
Lithium-Ion
Approx. Run Time BOL (Beginning of Life)
60 minutes
Approx. Run Time EOL (End of Life)
35 minutes (discontinue use and take to recycling center)
Battery Box Receptacle
IP65 / IP67 (not required for UL)
Run Time Hour Meter
Acts as “odometer for battery” and runs only when motor switch is ON
Approx. Charge Cycles
400 @ 100% discharge / 500 @ 80% discharge
Cut off Voltage (fully discharged)
30V
Charger Specifications
Approx. Charge Time
5.5 hours
Charger Amps
4 Amps
Charge Voltage
42V DC
Charger Voltage
110-240VAC / 36VDC (240VAC version only needs correct plug for wall outlet)
Charging Robustness
No special instructions
Battery Charge Memory
None
Battery Charge Gauge
Yes, LED Indicator
Approx. Charge Cycles
400 @ 100% discharge / 500 @ 80% discharge
Storage/Inventory:
Storage & Operation Ambient Temp
32
0
F (0
0
C) to 80
0
F(27
0
C)
Storage & Shipping Charge
40-60% Charge (35-38VDC)