background image

58

EN

Electric schematic diagram

TUBE 

TUBE TEMP.

RT2

SENSOR

WATER LEVEL

SWITCH

SENSOR

RT3

OUTTUBE TEMP.

OUTTUBE 

YEGN

PE

PE

ELECTRIC BOX

PE

PE

SENSOR

C2

RD

FAN

MOTOR

BN

M1

YEGN

M2

RT1

AP2

DISP1

ROOM TEMP.

DISP2

RD

W7

W6

HIGH-WP

BK

WH 

COM

NC

SA

BU

W1

DISP1

BU

WH

BK

YE

RD W4

FAN

RD

W2

DISP2

WATER(WATER1)

N1

AP1

COMP

L

K201

C1

YE

W3

C

YEGN

COMP.

S

W5

N3

BU

BU(WH)

YEGN(GN)

N

BN(BK)

L

POWER

ROOM

WATER MOTOR

R(M)

COMP.

MOTOR

Summary of Contents for KPC-09AI

Page 1: ......

Page 2: ...PC 09AI Thank you for choosing our product For proper operation please read and keep this manual carefully If you have lost the Owner s Manual please contact the local agent or visit www kaisai pl or...

Page 3: ...recovery 43 Malfunction Malfunction analysis 44 Attached sheet Drainage way 57 Electric schematic diagram 58 This marking indicates that this product should not be disposed with other household waste...

Page 4: ...0cm 30cm 30cm Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision persons with reduced physical sensory ormental capabilities or...

Page 5: ...nage hose nearby temperature can t lower than 0 Otherwise it will cause water leakage to air conditioner Prohibit inserting any objects into the air conditioner Do not repair or disassemble the air co...

Page 6: ...5 4 4 6 6 7 7 8 8 11 11 12 12 13 13 9 9 14 14 15 15 control panel handle 3 3 vertical louver horizontal louver air outlet castor heat removal pipe 10 10 joint B joint A air outlet condenser plug of p...

Page 7: ...press or button to increase or decrease set temperature 1 C F Set temperature is range is 16 C 61 F 30 C 86 F Under auto drying or fan mode this button is invalid Press this button and the mode will c...

Page 8: ...AN button SWING button SLEEP button 7 TIMER button AUTO OPERATION COOL OPERATION DRY OPERATION FAN OPERATION HEAT OPERATION TIMER ON TIMER OFF SIGNAL SENDING SWING OPERATION SLEEP OPERATION LOCK SET S...

Page 9: ...t temperature Press FAN button to adjust fan speed After selecting COOL mode air conditioner will operate under cooling mode speed Fan speed can t be adjusted After selecting DRY mode air conditioner...

Page 10: ...and H flash to Under AUTO fan speed air conditioner will select proper fan speed according to ex factory setting Fan speed can t be adjusted under DRY mode to your required time Press TIMER button to...

Page 11: ...ame mode batteries If you won t use your remote controller for a long time take out the batteries If display on remote controller is light or no display please replace batteries Press the position mar...

Page 12: ...er to turn 2 Press MODE button to select your required operation mode AUTO COOL 3 Press or button to set your required temperature temperature can t on the air conditioner DRY FAN adjusted under AUTO...

Page 13: ...e fig and then remove the filter 1 b Pull out the filter 2 Use cleaner or water to clean the filter If the filter is very dirty such as grease use warm water 40 C 104 F melted with neutral abluent to...

Page 14: ...in chassis refer to the section of discharge me thod for details 5 Check whether window bracket is damaged or not If yes please contact dealer Long time storage If you don t use the air conditioner f...

Page 15: ...her there s fluorescence Whether air outlet or air inlet is within the receiving range low lamp in the room blocked Under heating mode whether indoor temperature is reached Whether heating mode is sta...

Page 16: ...e unit again panel due to change of temperature which cause friction sound will resume operation Malfunction code Chassis is full of water Malfunction of ambient temperature sensor Please contact prev...

Page 17: ...es such as welding machine medical eq 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circumstances 1 Air inlet should...

Page 18: ...yellow green wire or green wire in air conditioner is grounding wire which 9 The grounding resistance should comply with national electric safety regulations 10 The appliance shall be installed in ac...

Page 19: ...plug drainage pipe battery 2 user s manual cross screwdriver straight screwdriver saw gauge scissors pencil AAA 1 5V wire hook 2 remote controller Optional accessories Optional accessories some models...

Page 20: ...the wire hook at the back of the unit with screws the direction of wire hook is Wind the power cord around the wire hook as shown in following fig direction of wire hook is upward wire hook screw dir...

Page 21: ...ght of rear side plate near drainage port with a screw 3 Put the drainage pipe into drainage port and screw it up and then bind it with pipe hoop 4 Put the rubber plug into the other side of drainage...

Page 22: ...exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown in figure When length installing it on wall height of hall...

Page 23: ...with 2 nuts spring washer washer and bolt spring washer spring washer washer washer bolt bolt support rain shield 4 Fix the rain shield on the support with 2 nuts spring washer washer and bolt Note p...

Page 24: ...rear connection plate required quantity is shown in the sheet below Window width W Screw quantity Clip quantity window sash window sash window sash clip of rear connection plate window frame windowsil...

Page 25: ...l with screws and clips of rear conn ection plate required quantity is shown in the sheet below Window height H Screw quantity Clip quantity window sash window sash window sash clip of rear connection...

Page 26: ...into the groove until you hear a sound clasp locating pole opening joint B correct correct correct wrong joint C groove the side with TOP is upwards 3 Aim the locating pole of joint B of heat discharg...

Page 27: ...e joint A Press the clasp and lift joint A upwards to remove it disassemble Operation test Put through the power supply and then press ON OFF button on remote controller to start the unit Press mode b...

Page 28: ...eration the condensation water will be drained to the chassis and When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed Move the unit to a suitable place for discha...

Page 29: ...UBE YEGN PE PE ELECTRICBOX PE PE SENSOR C2 RD FAN MOTOR BN M1 YEGN M2 RT1 AP2 DISP1 ROOMTEMP DISP2 RD W7 W6 HIGH WP BK WH COM NC SA BU W1 DISP1 BU WH BK YE RD W4 FAN RD W2 DISP2 WATER WATER1 N1 AP1 CO...

Page 30: ......

Page 31: ......

Reviews: