53
E02
Target Superheat for Heating
-20.0~20.0
℃
5
℃
E03
EEV Initial Steps for Heating
0~500N
350
E07
EEV Min. Steps
0~500N
100
E08
EEV Initial Steps for Cooling
0~500N
200
E09
EVI EEV: Adjustment Mode
0-
【
Manual
】
/1-
【
Auto
】
1
E10
EVI EEV: Initial Steps
0~500N
350N
E13
EVI EEV Target Superheat Degree
-20.0~20.0
℃
3
℃
E14
EVI EEV Min. Steps
0~500N
100N
E17
Defrosting EEV Steps
10~500N
480
E18
Target Superheat for Cooling
-10.0~10.0
℃
3
℃
E19
EEV Adjustment Range In Smart Mode
0%--300%
20
0%--300%
D
Defrost parameters
D01
Ambient Temp. of Starting Defrosting
-37~45
℃
12.5
℃
D02
Heating Operation Time Before Defrosting
0~120min
26 min
D03
Interval Time Between Defrosting Cycles
30~90min
45 min
D04
Exhaust Temp. Correction for Defrosting Cycle
0~150
℃
110
℃
D05-1
Defrosting Suction Pressure 1
0~45bar
2.6bar
D05-2
Defrosting Suction Pressure 2
0~45bar
1.7bar
D06
Defrosting Cycle Time Correction
0~120min
15 min
D07
Ambient Temp. of Start Sliding Defrosting
-37~45
℃
6.1
℃
D08
Suction Temp. of Start Sliding Defrosting
-37~45
℃
-4.1
℃
D09
Ambient Temp. of Stop Sliding Defrosting
-37~45
℃
-26.1
℃
D10
Suction Temp. of Stop Sliding Defrosting
-37~45
℃
-28.1
℃
D11
Min. Inlet Water Temp. of Defrosting
4~65
℃
23
℃
D12
Suction Pressure of Forced Defrosting
0~45bar
2bar
D13
Heating Operation Time Before Forced Defrosting
0~120min
120 min
D14
Fan Motor Power Ratio to Extend Defrosting Cycle
0 - 5.00
1.30
D15
Fan Motor Power Ratio to Enter Forced Defrosting
0 - 5.00
1.50
D16
Max. Fan Motor Power to Enter Forced Defrosting
50 - 1000W
200W
D17
Coil Temp. of Exit Defrosting
-37~45
℃
13
℃
D18
Distributor Tube Temp. of Exit Defrosting
-37~45
℃
33
℃
D19
Max. Defrosting Time
0~20min
8 min
D20
Defrosting Frequency
30~90Hz
70Hz