35
The ground fault circuit interrupter must be a high-speed type
breaker of 30 mA (<0.1 s).
NOTE
Stated values are maximum values (see electrical data for exact values).
OUTOOOR UNIT POWER SUPPLY
22kW
18kW
26kW
30kW
Unit
Maximum
overcurrent
protector(MOP)
18
21
24
28
Wiring size(mm
2
)
6
6
6
6
9.7.4 Specifications of standard wiring components
Door 1: compressor compartment and electrical parts: XT1
9.7.5 Connection for system parallel
POWER SUPPLY
380VAC~3N
FUSE
L1
L2
L3
N
BLACK
BLUE
GRAY
BROWN
LPS
L1 L2 L3 N
L1
L2
L3
N
BLACK
BLUE
GRAY
BROWN
Power supply
Please use the shielded wire, and the shield layer must be grounded.
On/Off switch
Fuse
Distribution box
Distribution box
Distribution box
Distribution box
The parallel system electrical control system connection diagram(3N~)
Master unit
Slave unit 1
H1 H2
Slave unit 2
H1 H2
Slave unit x
H1 H2
Build-out resistor
Only the last IDU
requires adding the
build-out resistor at
H1 and H2.
......
SW9
ON
OFF
SW9
Master unit
Slave unit
L1 L2 L3 N
Fuse
L1 L2 L3 N
Fuse
L1 L2 L3 N
Fuse
L1 L2 L3 N
1
、
The parallel function of the system only supports 6 machines at most .
2
、
In order to ensure the success of automatic addressing, all machines must be connected to the same power
supply and powered on uniformly.
3
、
Only the Master unit can connect the controller, and you must put the SW9 to “on” of the master unit, the slave unit
cannot connect the controller .
4
、
Please use the shielded wire, and the shield layer must be grounded.
CAUTION
36
Port provide the control signal to the load.Two kind of control signal port:
Type 1
:
Dry connector without voltage.
Type 2
:
Port provide the signal with 220V voltage. If the current of load is <0.2A, load can connect to the port directly.
If the current of load is ≥0.2A, the AC contactor is required to connected for the load.
Control signal port of hydraulic model contains terminals for solar energy, remote alarm, 3-way valve, pump,and external heating
source, etc.
The parts wiring is illustrated below:
Type 2:
13
7 5 3 1 A1
A2
2
4
6
8
TBH
Power supply
Contactor
N
16
Type 1:
Load
Running
L N
FUSE
30 26
R1 R2
1) For solar energy kit input signal
SL1 SL2
1
2
CONNECT TO SOLAR
PUMP STATION
230VAC INPUT
Voltage
Maximum running current(A)
Wiring size(mm
2
)
220-240VAC
0.2
0.75
9.7.6 Connection for other components
1
SL1
2
SL2
3
H
4
C
5
6
1ON
7
1OFF
8
9
10
11
12
24
23
N
21
N
20
IBH1
19
18
13
14
L1
15
16 17
N
22
25
HT
29
30
31
DFT2
32
DFT1
26
R2
27
ASH1
28
ASH2
1
A
2
B
3
X
4
Y
5
E
6
P
7
Q
8
E
9
H1
10
H2
2ON
2OFF
P_c P_o P_s P_d
N
R1
TBH
N
N 3ON
3OFF
N
N
CN11
CN7
CN30
Code
Connect to
1
SL1
2
SL2
3
H
4
C
15
L1
5 1ON
6 1OFF
16
N
7 2ON
8 2OFF
17
N
9 P_c
21
N
10 P_o
22
N
11 P_s
12 P_d
24
N
13 TBH
16
N
14 IBH1
17
N
18
19 3ON
N
23
③
①
Solar energy input
signal
②
Room thermostat input
(
high voltage
)
Tank booster heater
Internal backup heater 1
SV3(3-way valve)
④
⑤
⑥
⑦
Outside circulation pump
(zone 1 pump)
Pumpc(zone 2 pump)
CN11
SV2(3-way valve)
SV1(3-way valve)
⑧
⑨
⑩
11
○
DHW pipe pump
23
N
SV1(3-way valve)
SV1(3-way valve)
Solar energy pump
20 3OFF
Code
Connect to
1
A
2
B
3
X
4
Y
5
E
6
P
7
Q
9
H1
10 H2
CN11
Wired controller
①
②
②
③
②
②
③
Code
Connect to
26
R2
30
R1
31 DFT2
32 DFT1
25
HT
29
N
27 AHS1
28 AHS2
①
CN7
Unit running state 0utput
Antifreeze E-heating
tape(external)
Additional heat source
Outdoor unit
system parallel
Defrost running output
41
40
Summary of Contents for KHC-22RY3
Page 1: ...INSTALATIONMANUAL MONO TYPE HEAT PUMP EN...
Page 2: ......
Page 79: ...16125300002403 V C 79...
Page 80: ...kaisai com...