If used as MULTI unit, please refer to the Installation & operation manuals packed with outdoor unit.

Summary of Contents for 12K

Page 1: ...PE INSTALLATION MANUAL Ceiling And Floor Type Thank you verymuch for purchasingour air conditioner Before using yourair conditioner please read thismanual carefully andkeep it forfuture reference INST...

Page 2: ...If used as MULTI unit please refer to the Installation operation manuals packed with outdoor unit...

Page 3: ...and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance shall not be installed...

Page 4: ...es a distance of 1 meter may not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditi...

Page 5: ...some models 1 on some models 1 1 2 on some models 2 on some models 6 Remote controller 7 Frame 8 Mounting screw ST2 9 0 C H 9 Alkaline dry batteries Am4 10 Remote controllermanual 11 Wirecontroller 12...

Page 6: ...eets the following requirements 1 INDOOR UNIT INSTALLATION All the pictures in this manual arefor explanation purpose only There may be slightly different fromthe air conditioner you purchased depend...

Page 7: ...squaretimber traversely over the roof beam then install thehanging screw bolts Inlaying or embeddingthe screw bolts Use embedding screwbold crock andstick harness Timber over thebeam Roof beam Ceilin...

Page 8: ...may shorten the life of the air conditioner 9 Since drain flows out of the outdoor unit do not place under the unit anything which must be kept away from moisture Cannot be installed hanging from ceil...

Page 9: ...atterns the wall height on the outlet side should be 1200mm or less 1 Installing outdoor unit 2 Drain work If drain work is necessary follow the procedures below Use drain plug for drainage If the dra...

Page 10: ...il Precautions 3 1 Flaring the pipe end 1 Cut the pipe end with a pipe cutter 2 Remove burrs with the cut surface facing downward so that the chips do not enter the pipe 5 Check that the flaring is pr...

Page 11: ...the check is complete wipe all soapy water off 7 Disconnect charging hose from gas stop valve s service port then fully open liquid and gas stop valves Do not attempt to turn valve rod byond its stop...

Page 12: ...tion Gas pipe Keep piping as short as possible and slope it downwards at a gradient of at least 1 100 so that air may not remain trapped inside the pipe Keep pipe size equal to or greater than that of...

Page 13: ...it body to wire the outdoor unit indoor units and the remote controller 11 The specification of power Minimum norminal cross sectional area of conductors Rated current of appliance A Nominal cross sec...

Page 14: ...m according to the figure 1 When attaching the control box lid make sure not to pinch any wires After all wiring connections are done fill in any gaps in the casing wiring holes with putty or insulati...

Page 15: ...ndensed of by the air conditioner have influenced your neighborhood Whether any of the refrigerant is leaked A protection feature prevents the air conditioner from being activated for approximately 3...

Page 16: ...for product improvement Consult with the sales agency or manufacturer for details QSDLI 016AEN CE 16122500000090 20150122 t to change without prior notice for product ncy or manufacturer for details 1...