PRECAUTIONS...................................................................................1
INSTALLATION INFORMATION..........................................................2
ACCESSORIES...................................................................................3
INDOOR UNIT INSTALLATION...........................................................4
OUTDOOR UNIT INSTALLATION.......................................................6
INSTALL THE REFRIGERANT PIPE...................................................8
CONNECT THE DRAIN PIPE............................................................10
ELECTRIC WIRING WORK...............................................................11
TWINS FUNCTION............................................................................13
TEST OPERATION............................................................................13

CONTENTS                                                                

Page

1

Keep this manual where the operator can easily find them. 

Read this manual attentively before starting up the units.

For safety reason the operator must read the following 

cautions carefully.

 

The safty precautions listed here are divided into two categories.

If you do not follow these instrutions exactly, the unit may 

cause property damage, personal injury or loss of life.

If you do not follow these instrutions exactly, the unit may 

cause minor or moderate property damage, personal injury.

After completing the installation, make sure that the unit operates 

properly during the start-up operation. Please instruct the customer on 

how to operate the unit and keep it maintained.Also, inform customers 

that they should store this installation manual along with the owner's 

manual for future reference.  

Be sure only trained and qualified service personnel to install, 

repair or service the equipment.

Improper installation, repair, and maintenance may result in 

electric shocks, short-circuit, leaks, fire or other damage to the 

equipment.

Install according to this installation instructions strictly. 

If installation is defective, it will cause water leakage, electrical 

shock and fire.

When installing the unit in a small room, take measures 

against to keep refrigerant concentration from exceeding 

allowable safety limits in the event of refrigerant leakage. 

Contact the place of purchase for more information. Excessive 

refrigerant in a closed ambient can lead to oxygen deficiency.

Use the attached accessories parts and specified parts for 

installation. 

otherwise, it will cause the set to fall, water  leakage, electrical 

shock and fire.

Install at a strong and firm location which is able to withstand 

the set' s weight. 

If the strength is not enough or installation is not properly done, 

the set will drop to cause injury.

The appliance shall not be installed in the laundry.

Before obtaining access to terminals, all supply circuits must 

be disconnected.

The appliance must be positioned so that the plug is accessible.

The enclosure of the appliance shall be marked by word, or by 

symbols, with the direction of the fluid flow.

For electrical work, follow the local national wiring standard, 

regulation and this installation instructions. An independent 

circuit and single outlet must be used. 

If electrical circuit capacity is not enough or defect in electrical 

work, it will cause electrical shock or fire.

Use the specified cable and connect tightly and clamp the 

cable so that no external force will be acted on the terminal. 

If connection or fixing is not perfect, it will cause heat-up or fire 

at the connection.

Wiring routing must be properly arranged so that control board 

cover is fixed properly. 

If control board cover is not fixed perfectly, it will cause heat-up 

at connection point of terminal, fire or electrical shock.

If the supply cord is damaged, it must be replaced by the 

manufacture or its service agent or a similarly qualified person 

in order to avoid a hazard.

An all-pole disconnection switch having a contact separation 

of at least 3mm in all poles should be connected in fixed wiring.

When carrying out piping connection, take care not to let air 

substances go into refrigeration cycle. 

Otherwise, it will cause lower capacity, abnormal high pressure 

in the refrigeration cycle, explosion and injury.

Do not modify the length of the power supply cord or use of 

extension cord, and do not share the single outlet with other 

electrical appliances. 

Otherwise, it will cause fire or electrical shock.

Carry out the specified installation work after taking into 

account strong winds, typhoons or earthquakes.

Improper installation work may result in the equipment falling 

and causing accidents.

PRECAUTIONS

WARNING

WARNING

CAUTION

3

kaisai.com

Summary of Contents for 12K

Page 1: ...PE INSTALLATION MANUAL Ceiling And Floor Type Thank you verymuch for purchasingour air conditioner Before using yourair conditioner please read thismanual carefully andkeep it forfuture reference INST...

Page 2: ...If used as MULTI unit please refer to the Installation operation manuals packed with outdoor unit...

Page 3: ...and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance shall not be installed...

Page 4: ...es a distance of 1 meter may not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditi...

Page 5: ...some models 1 on some models 1 1 2 on some models 2 on some models 6 Remote controller 7 Frame 8 Mounting screw ST2 9 0 C H 9 Alkaline dry batteries Am4 10 Remote controllermanual 11 Wirecontroller 12...

Page 6: ...eets the following requirements 1 INDOOR UNIT INSTALLATION All the pictures in this manual arefor explanation purpose only There may be slightly different fromthe air conditioner you purchased depend...

Page 7: ...squaretimber traversely over the roof beam then install thehanging screw bolts Inlaying or embeddingthe screw bolts Use embedding screwbold crock andstick harness Timber over thebeam Roof beam Ceilin...

Page 8: ...may shorten the life of the air conditioner 9 Since drain flows out of the outdoor unit do not place under the unit anything which must be kept away from moisture Cannot be installed hanging from ceil...

Page 9: ...atterns the wall height on the outlet side should be 1200mm or less 1 Installing outdoor unit 2 Drain work If drain work is necessary follow the procedures below Use drain plug for drainage If the dra...

Page 10: ...il Precautions 3 1 Flaring the pipe end 1 Cut the pipe end with a pipe cutter 2 Remove burrs with the cut surface facing downward so that the chips do not enter the pipe 5 Check that the flaring is pr...

Page 11: ...the check is complete wipe all soapy water off 7 Disconnect charging hose from gas stop valve s service port then fully open liquid and gas stop valves Do not attempt to turn valve rod byond its stop...

Page 12: ...tion Gas pipe Keep piping as short as possible and slope it downwards at a gradient of at least 1 100 so that air may not remain trapped inside the pipe Keep pipe size equal to or greater than that of...

Page 13: ...it body to wire the outdoor unit indoor units and the remote controller 11 The specification of power Minimum norminal cross sectional area of conductors Rated current of appliance A Nominal cross sec...

Page 14: ...m according to the figure 1 When attaching the control box lid make sure not to pinch any wires After all wiring connections are done fill in any gaps in the casing wiring holes with putty or insulati...

Page 15: ...ndensed of by the air conditioner have influenced your neighborhood Whether any of the refrigerant is leaked A protection feature prevents the air conditioner from being activated for approximately 3...

Page 16: ...for product improvement Consult with the sales agency or manufacturer for details QSDLI 016AEN CE 16122500000090 20150122 t to change without prior notice for product ncy or manufacturer for details 1...