![KAESER KOMPRESSOREN EPC-2-G Series Assembly And Operating Manual Download Page 28](http://html1.mh-extra.com/html/kaeser-kompressoren/epc-2-g-series/epc-2-g-series_assembly-and-operating-manual_3183670028.webp)
Extending or modifying the compressor station
➤ If a compressor station is to be extended or changed,
check the blow-off capacity of the pressure relief valves on air receivers and pipework before
installing the new devices.
➤ Pressure relief valves of insufficient blow off capacity
must be replaced by valves with a higher capacity.
3.5.2 Safe machine operation
Information on safe conduct when handling the machine is found here.
Transport
➤ Use suitable lifting gear that conforms to local safety regulations.
➤ Allow transport only by personnel trained in the safe movement of goods.
➤ Attach lifting gear only to suitable lifting points.
➤ Note the centre of gravity to avoid danger of the machine tipping over.
➤ Make sure the danger zone is clear of personnel.
Installation
➤ Install the machine in a suitable compressor room.
➤ If installed outdoors, the machine must be protected from frost, direct sunlight, dust, rain and
splashing water.
➤ Do not operate in areas in which specific requirements with regard to explosion protection are in
force.
For instance, the requirements of ATEX directive 94/9/EC "Equipment and Protective Systems
intended for use in Potentially Explosive Atmospheres".
➤ Ensure adequate ventilation.
➤ Ensure that required ambient conditions are maintained with regard to:
■ Ambient temperature and humidity
■ Clean inlet air with no damaging contaminants.
■ Inlet air free of explosive or chemically unstable gases or vapours.
■ inlet air free of acid/alkaline forming substances, particularly ammonia, chlorine or hydrogen
sulphide.
➤ Do not position the machine in warm exhaust air from other machines.
➤ Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance.
Decommissioning, storage, disposal
➤ Drain out fluids and dispose of according to environmental regulations.
These include, for example, lubricating oil and compressor oil.
➤ Dispose of the machine in accordance with local environmental regulations.
3.5.3 Organisational Measures
➤ Designate personnel and their responsibilities.
3
Safety and Responsibility
3.5
Dangers
18
Assembly and operating manual 2-stage piston compressor
EPC-2-G
No.: 9_5753_04 E