NOTE
Power reduction due to heat accumulation!
If the recommended minimum clearances are not observed, the device may go into power regulation
mode due to insufficient ventilation and the resulting heat build-up.
›
Observe the minimum clearances and provide for sufficient heat dissipation.
›
Any objects on the housing of the device must be removed prior to operation.
›
Make sure that foreign objects cannot hinder heat dissipation following installation of the device.
Lifting and mounting the device
↻
The mount has been installed.
1 Lift the device using the lateral openings. Have regard to the position of the device's center of gravity!
NOTE: Do not lift the device by the lid or cover!
2 Fit the device onto the upper mount by means of the mounting bracket. Fit the device onto the lower mounting
bracket in full so that the device sits flush with its rear side on the mount. ( [See figure 11] [
Page 17]).
3 Insert the screw provided into the lug of the mount and secure the device to prevent it from being lifted off [ T30 /
NOTE: Alternatively: At this point, the screw mentioned above can be replaced with a special-purpose screw for
protection against theft.
»
The device is installed. Proceed with the electrical installation.
7
Installation
7.1
General
DANGER
Lethal voltages are still present in the connections and cables of the device even after the device has
been switched off and disconnected!
Severe injuries or death may occur if the cables and/or terminals/busbars in the device are touched.
›
The device must be mounted in a fixed position before being connected electrically.
›
Observe all safety regulations and current technical connection specifications of the responsible power
supply company.
›
The device may only be opened and serviced by an authorized electrician.
›
Switch off the grid voltage by turning off the external circuit breakers.
›
Check that all AC and DC cables are completely free of current using a clip-on ammeter.
›
Do not touch the cables and/or terminals/busbars when switching the device on and off.
›
Keep the device closed when it is in operation.
↻
NOTE: S version: The device is shut down externally at the combiner box.
1 Switch the DC isolator switch from 1 (ON) to 0 (OFF).
2 Press in the safety catch (1) from behind.
3 Attach the hanging lock (2) to the safety catch.
DANGER! A measurement in a live state may be required for tests. Only appro-
priately qualified electricians authorised by the mains supply network opera-
tor are permitted to open and maintain the device.
DANGER! Observe all safety regulations against harmless contact with live ma-
terials.
1
2
Fig. 12:
Lock DC circuit breakers to
prevent reconnection.
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
KACO blueplanet 137 TL3 KACO blueplanet 150 TL3
Page 18
EN-US