General data
Certification
Overview: see homepage, download area
4.3
Environmental data
Environmental conditions
Max. installation height
9842 ft (Derating at 6561 ft)
Installation distance from
coast
>1640 ft
Ambient temperature of
-13 °F - 140 °F
Power derating from
> 113 °F
Protection rating (KACO in-
stallation site)
IP66 /NEMA 4X
Relative humidity, non-con-
densing (in operation)
100 %
4.4
Accessories
Accessory articles
KACO order no.
KACO blueplanet DC-Breaker
1001860
Bending box
1001917 (absolutely mandatory for UL market!)
Accessory articles
KACO order no.
Bending box
1001917
AC inverter input plate kit
1001882 (double row) / 1001906 (M63/32)
AC inverter overvoltage protection kit
1001884
AC inverter overvoltage protection kit
1001884
DC inverter overvoltage protection kit
1001885
LAN inverter overvoltage protection kit
1001886
RS485 inverter overvoltage protection kit
1001887
PID connection set
1001888
WLAN adapter, Digitus 150N micro
3013222
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
KACO blueplanet 137 TL3 KACO blueplanet 150 TL3
Page 13