![Kaco 1000335 Manual Download Page 39](http://html1.mh-extra.com/html/kaco/1000335/1000335_manual_649206039.webp)
Country-
spec. Set-
tings
Men
u
level
Display/
Setting
Action in this menu/meaning
4
1
2
3
4
Settings
F
Open the menu: Press the
Right arrow button
or
Enter
button
.
4
1
2
3
Language
F
Select the required language for the user interface.
4
1
2
3
Def. total yield
NOTE: You can set the total yield to any value, for example, when you
have received a replacement device and want to continue the record-
ing from the present value.
F
Select the
Save
button and confirm with the
Enter button.
4
1
2
3
Interface
NOTE: The address must not be the same as the address of another
device or a Powador-proLOG device
.
F
Assign a unique RS485 bus address to the device.
4
1
2
3
Priwatt
F
Open the menu: Press the
Right arrow button
or
Enter
button
.
4
1
2
3
4
Activation mode
NOTE: Re-activation depends on the operating mode selected and on
the activation conditions.
F
Activate function for a cycle
4
1
2
3
4
Monitoring time
F
Set time span during which the power threshold must be exceeded
without interruption.
4
1
2
3
4
Power threshold
F
Set power threshold from which the monitoring time up to activation
begins.
4
1
2
3
4
Operation mode
1 Power-dependent: the function remains active until below the set
power threshold.
2 Time-dependent: The function is active independent of the sunlight
for the set operation time.
4
1
2
3
4
Operation time
NOTE: The menu option is only available in "Time-dependent" opera-
tion mode.
F
After connection, the function is active for the set operation time.
4
1
2
3
Quick start
F
Reduce the waiting times during the self-test by pressing
the
Activate
button.
4
1
2
3
Logging interval
F
Specify the time period between 2 log data recordings.
4
1
2
3
Log data backup
NOTE: The device supports the backing up of all recorded yield data to
a connected USB storage device.
F
Activate or deactivate log data backup
4
1
2
3
Display
1 Configure the contrast setting for the display.
2 Set the length of time without user input after which the backlight-
ing of the LCD switches off.
3 Alternatively: Permanently activate or disable the backlighting by
selecting "
On
" or "
Off
".
4
1
2
3
Date & time
NOTE: For self-diagnostics, the device performs a restart on a daily
basis at 0:00 hours. To avoid having a restart occur during feed-in op-
eration and to always obtain reliable log data, ensure that the time is
correctly set.
F
Set the date and time.
4
1
2
3
Network
Open the menu: Press the
Right arrow button
or
Enter but-
ton
.
Powador 30.0-72.0 TL3
Page 39
EN