Kabola Boiler-CH User Manual Download Page 19

19 

Manual COMPACT 7 version 2018

 

 

6 Cleaning and maintenance

 

 

6.1 Points for attention

 

 

Replacement parts must be ordered from Kabola Heating Systems. Only original replacement parts may 
be used for the guarantee to be applicable. Mention the type and serial number when ordering. Kabola 
Heating Systems can then supply the correct parts. Annex E includes a summary of the parts. 

 
 

 

 

6.2 Cleaning and maintenance

 

 

 

Warning:

 

  

Carry  out  maintenance  and  repair  activities  when  the  boiler  is  switched  off 
because the boiler could unexpectedly start up. Remove the plug from the wall 
socket.  

 

Warning:

 

Maintenance and repair activities must be carried out by an accredited 
installer or a service technician from Kabola Heating Systems. 

 

Annually

 

1.  Clean the boiler; 

1.1.  Remove the oil burner; 
1.2.  Remove the boiler door; 
1.3.  Remove the boiler gasket. 
1.4.  Clean the inside of the boiler using a pipe cleaner; 

 

Note:

 

Do not use any aggressive cleaning products when cleaning. 

 

1.5.  Suck the heating boiler empty with a vacuum cleaner; 
1.6.  Replace the boiler gasket; 
1.7.  Replace the boiler door; 

2.  Clean the flue if necessary. 
3.  Replace the oil filter cartridge; 
4.  Clean the burner (see burner manual). 
5.  Replace the nozzle; 
6.  Replace the electrode block if required; 
7.  Replace the photocell if older than 5 years; 

 

Note:

 

The old oil filter cartridge must be processed as chemical waste. 

 
 

It is advised to have the burner settings inspected and adjusted each year by a service technician 
certified by Kabola Heating Systems. 

 

 

7 Disposal

 

 

When disposing of the boiler the following points are important for reasons of safety: 

  Dispose of the oil filter and the oil hoses as chemical waste; 

  Separate the metal parts and plastic parts and dispose of them separately; 

  Dispose of any oil in an environmentally friendly way; 

  Transport the discarded boiler according to the instructions in section 3; 

  Dispose of this manual with waste paper

Summary of Contents for Boiler-CH

Page 1: ...1 User Guide Compact 7 series Boiler CH Calorifier Combi...

Page 2: ...ip gives the user suggestions and advice to be able to carry out certain tasks more easily Note The user is given additional information here Any potential problems are also covered Warning Chance of...

Page 3: ...ng system 7 4 1 3 Flue gas extraction 9 4 1 4 Electrical connection 11 4 1 5 Filling the central heating system for the Compact 7 central heating boiler 13 4 1 6 Connecting the oil filter 14 4 2 Bring...

Page 4: ...the space in which they are installed Heating only takes place using radiators a hot air system underfloor heating and or any custom made airco systems in which the Kabola COMPACT 7 is integrated When...

Page 5: ...COMPACT 7 boiler MEASURES FOR SAFE INSTALLATION Do not place any flammable and or gaseous substances that may cause danger of explosion or fire in the space where the boiler is or is to be installed...

Page 6: ...wing points must be observed Make sure that the casing cannot be damaged Use a blanket for example Transport the boiler upright with the base below 3 2 Storage When the boiler is to be stored for long...

Page 7: ...with bolts or tack welding Make sure there is a distance between the outlet and the wall of at least 10 20 mm because of the heat transfer from the flue gas outlet Ensure sufficient space around the b...

Page 8: ...point 1 6 Assemble the central heating return and boiler pipe at point 2 7 Assemble the boiler supply pipe at point 3 8 Assemble the separately supplied filler tap and drain combination at point 4 see...

Page 9: ...e flue gas outlet horizontally from the boiler through the wall The following points must then be respected The maximum permitted length without bends is 3 metres Make sure that the outlet is amply ab...

Page 10: ...ce The maximum permitted length with a vertical system is 5 meters With a vertical outlet always use a drain Figure 5 Tip Kabola can manufacture a deck hole at an angle so the flue is straight as cust...

Page 11: ...er Tip If you use a transformer we advise using a 900W sine wave transformer Do not place the room thermostat near a heat source Figure 6 Compact 7 central heating boiler Connection of the room thermo...

Page 12: ...the plug see fig 11 Connect the wires for the hot water on off function to points S3 and B4 as shown on the sticker on the plug frostguard see fig 11 The two boiler thermostat wires only need to be c...

Page 13: ...n off switch button lights Put the heating pump in automatic venting position Control knob to 12 hours see Figure 9 Turn a quarter of a turn the red button after about 5 minutes to position 3 see Figu...

Page 14: ...e oil filter no branch point for other oil users Connect the two oil hoses from the burner to the oil filter Note the arrows Make sure that the arrow directions of the oil pump and the oil filter corr...

Page 15: ...grees higher than the ambient temperature also see the room thermostat manual Open the fuel tank valve Open the oil filter valve by turning the red button to the left fully open If the red failure oil...

Page 16: ...ime Circulation pump operates for 3 minutes The figure 19 on the right of the display shows the current boiler water temperature 5 Operation Compact 7 CH Operating panel Compact 7 CH front Figure 15 1...

Page 17: ...ning time 0 seconds Flashing point hot water off Point lit up hot water stand by The figure 19 on the right of the display shows the current boiler water temperature Compact 7 Calorifier Operating pan...

Page 18: ...Tap comfort position Boiler kept at temperature Flashing point hot water off Point lit up hot water stand by The figure 19 on the right of the display shows the current boiler water temperature Compac...

Page 19: ...nside of the boiler using a pipe cleaner Note Do not use any aggressive cleaning products when cleaning 1 5 Suck the heating boiler empty with a vacuum cleaner 1 6 Replace the boiler gasket 1 7 Replac...

Page 20: ...Annex A Technical specifications Manual COMPACT 7 version 2018 20...

Page 21: ...Annex B Electrical diagram 230 V Compact 7 central heating boiler...

Page 22: ...22 Manual COMPACT 7 version 2018 Annex C Electrical diagram 230 V Compact 7 Calorifier and Combi...

Page 23: ...t the oil filter Burner failure Voltage too low Check voltage level Nozzle defect Replace the nozzle Boiler does not respond to room thermostat Room thermostat battery is flat Replace the battery Room...

Page 24: ...24 Manual COMPACT 7 version 2018 Annex E Boiler parts and burner parts To order parts we refer you to our website www kabola nl You can download the part lists under the downloads header...

Page 25: ...25...

Page 26: ...sponsibility that the product Boiler burner Kabola COMPACT 230 V to which this declaration relates conforms with the following standards EN 303 1 EN 303 2 EN 304 EN 50081 1 EN 50082 1 EN 61010 accordi...

Page 27: ...Annex G Warranty Conditions 27...

Reviews: