18
Manual COMPACT 7 version 2018
Numbers
Explanation
Photo
0
Rest position (boiler is on stand-by)
Circulation pump stopped
1
Room thermostat demands heat.
Circulation pump operating
2
Hot water is drawn off. Circulation pump
operating
3
Circulation pump further running time.
Circulation pump operates for ± 3
minutes
4
Tap comfort position
Boiler kept at temperature
Flashing point = hot water off
Point lit up = hot water stand-by
The figure (19) on the right of the display shows the
current boiler water temperature
Compact 7 combi
Operating panel Compact 7 combi (front)
Figure 18
10 Amp fusing
High limit thermostat (is found on the back)
On/off switch
Display boiler thermostat
Explanation of the operating panel
Set the boiler temperature to 80 degrees Celsius (press boiler thermostat button in and turn).
Key to the
combi
boiler
display