INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4 • PK3197_10_14
For
Contactless card readers:
present
a new initialization keycard, programmed
by the new FDU/ATLAS System, to the
contactless reader. The green LED on
the contactless reader should turn off in
sequence: rapid twice, followed by normal
once. Alternatively the controller board (B)
can be verified to ensure that LED D41 is
on.
5.4 Programming and Auditing
IMPORTANT:
Programming of the RAC 4 can only
be done with the following versions of
programming device software:
- ATLAS: software version 1.0 or higher
-
Kaba Ilco 780 FDU: software version
6.40 or higher
- Kaba Ilco FDU 4 (G4): all versions
The RAC 4 can be programmed using either
an FDU or ATLAS system. Refer to the
appropriate steps below based on the hotel’s
programming system.
NOTE:
-
If a Remote Programming Interface
(RPI) is connected the RAC 4 can be
programmed directly via the connector in
the RPI.
-
Unlike Kaba’s electronic locks a
Programming keycard is not required
for the RAC 4 as the system is already in
programming mode.
FDU Programming
1. Link the FDU to the DB1 in the RPI box, or
to the DB9 connector (serial port J5) on
the controller PCB. Refer to figure 20 for
the positions of the relevant connectors.
2.
For step-by-step programming
instructions refer to the Kaba Ilco Lodging
Access Control Reference Manual.
ATLAS Programming
For ease of programming the IPM kit for RAC
(PN 064-511161) can be used by attaching the
IPM to the RAC with the Velcro provided in
the kit.
-
Cut a piece of each type of Velcro from
the strip provided.
-
Depending on the configuration of the
system attach one side of the Velcro to
either the side of the RPI, or to the side of
the RAC 4 enclosure.
-
Attach the other side to the side of the
IPM.
1. Connect one side of the DB-9 serial cable
to the IPM.
2.
Connect the other side to the DB-9
connector (serial port J5) on the controller
PCB of the RAC 4.
3.
For step-by-step programming
instructions refer to the ATLAS on-line help
or the ATLAS Administration manual.
Figure 20
Page 15
DB9 Cable
FDU
RAC 4
RAC 4
DB9 Cable
DB9 Cable
IPM
DB9 Cable
RPI
FDU