Page 2
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4 • PK3197_10_14
4. Motion Detector
Refer to Annex B, Figure 9 for detailed
wiring.
Mount the device at the desired location
and run a 4-conductor cable from the
motion detector relay’s terminal block to
controller PCB connector J8, pins 3 & 4.
To power the motion detector, connect
the +12V input of the motion detector to
the red wire connecting the +DC OUT
terminal on the power supply and the 12V
input of the controller PCB (J16, pin 1),
as shown in Figure 8 of Annex B. Then
connect the GND input of the motion
detector to the black wire connecting the
-DC OUT terminal on the power supply
and the GND input on the controller PCB
(J16, pin 2). The use of wire connectors /
caps is recommended to ensure reliable
electrical connections.
5. Remote Programming Interface (RPI)
Refer to Annex B, Figure 10 for detailed
wiring.
Run a 4-conductor cable from the RPI to
terminal block J6 on the controller PCB.
Connect as per Annex A, Table 3.
6. Fire Alarm Panel
Refer to Annex B, Figure 11 for detailed
wiring.
Remove the jumper wire connected
between pins 3 and 4 of connector J18 on
the controller PCB and complete the fire
panel installation as per manufacturer’s
indications.
Step 8: Install strain relief bushing
(for power adaptor only)
One strain relief bushing (item ‘S’ – see Figure
10) is provided in the hardware bag to secure
the power adaptor cable leading into the RAC
4 enclosure to help prevent the possibility of
wire tampering.
1. Remove the keyhole knock-out on from
the inner side of the enclosure using a
hammer and screwdriver or awl to tap
out the small metal disk.
2.
Determine the routing needed for the
wiring of the power adaptor from the AC
power source to the enclosure.
3. Open the strain relief bushing and route
the power adaptor cable in. Leave enough
cable length to plug the power adaptor’s
connector into the power jack inside the
enclosure. To obtain the desired strain
relief effect, firmly close the plug of the
bushing onto the flat cable.
4. Attach the strain relief bushing with cable
onto the enclosure, and connect the
power adaptor’s connector to the power
jack on the inside of the enclosure.
5. If using the International Power Adaptor,
attach the appropriate AC outlet prong to
the power adaptor.
Step 9: Completing the installation
1. I f the access door was removed, reinstall
the door on the RAC 4 enclosure.
2.
Bend the two tabs of the access door
with pliers to a maximum of 30 degrees as
shown in Figure 14.
3. Plug the power adaptor into the AC power
source.
Page 13
Figure 19
S
J
I
Figure 18
OR