INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4 • PK3197_10_14
5.1 Testing
1. If not already done, connect the AC power
adaptor, and / or turn on the AC current.
2.
Verify that the Func1 (D45) and Func2
(D46) LEDs on the controller board (B)
blink continuously.
3. Activate the Bypass switch, SW3 on the
controller board (B).
4. Verify that the locking device is activated.
NOTE:
If the locking device is not activated,
verify that the Fire Alarm input is
properly connected, or a jumper wire
is connected.
5. De-activate the bypass switch, SW3 on the
controller board (B).
6. As per the FDU or ATLAS manuals make
a test card and use it on the card reader.
Verify that the door unlocks. The unlock
time will correspond to the delay set by the
DIP switches as per Annex A, Table 4.
NOTE:
The Test card will only unlock the
door if the RAC 4 has never been
initialized.
7. If a request to Exit (REX) button is connected,
press it and verify that the door unlocks.
8. If a Remote Unlock button is connected,
press it and verify that the door unlocks.
9. If the RAC 4 is connected to a fire panel and
the electromagnetic lock powered by the
12 VDC output of the RAC 4, verify that the
electromagnetic lock or a fail-safe electric
strike is deactivated when the fire alarm is
active (open input).
10. The RAC 4 is now ready to be Initialized
and Programmed.
5.2 Hotel ID Initialization
1. As per the appropriate instruction manual,
create an initialization keycard with the FDU
or ATLAS system.
2. For
swipe card readers:
swipe the
initialization keycard through the swipe
card reader. The red and green LEDs on the
swipe card reader should flash in sequence:
red + green once, followed by green once.
Alternatively, the controller board can
be verified to ensure that LED D41 is ON.
For
insert card readers:
insert
the initialization keycard into the
insert card reader. Verify that LED41
on the controller board (B) is on.
For
Contactless card readers:
present
the initialization keycard to the reader.
The green LED on the Contactless reader
should turn off in sequence: rapid twice,
followed by normal once. Alternatively,
the controller board (B) can be verified to
ensure that LED D41 is on.
5.3 Hotel ID Re-initialization
In the event the Hotel ID code of the premise
is changed with a new FDU or ATLAS
configuration, or a problem is suspected with
the current configuration, the RAC 4 will need
its Hotel ID to be re-initialized.
1.
Note down the current DIP switch bank
SW2 settings on the controller board (B)
as this is the current delay setting for the
peripherals used.
2. Set the switches on DIP switch bank SW2
on the controller board (B) to CFG #16 (OFF,
OFF, OFF, OFF) as per Annex A, Table 4.
3.
Verify that the initialization LED (D41) is
OFF.
4. Set the DIP switch positions back to the
chosen access delay settings as noted
above, or reset based on values shown in
Annex A, Table 4.
5. For
swipe card readers:
swipe a new
initialization keycard, programmed by the
new FDU/ATLAS system, through the swipe
card reader. The red and green LEDs on
the card reader will flash in sequence: red
+ green once, followed by green once.
Alternatively the controller board (B) can
be verified to ensure that LED D41 is ON.
For
insert card readers:
insert a new
initialization keycard, programmed by the
new FDU/ATLAS system, into the insert
card reader. Verify that LED D41 on the
controller board (B) is ON.
Page 14
5.0
Settings and Operation