![Kaba E-Plex 5000 Operation Manual Download Page 30](http://html.mh-extra.com/html/kaba/e-plex-5000/e-plex-5000_operation-manual_649018030.webp)
26
Summary of Pushbutton Programming Commands
Name
Configure
Command
000 #
MMMMMMMM#
MMMMMMMM#
001 #
MMDDYY#
MMDDYY#
002 #
HHMM#
HHMM#
003 #
NNNN#
004 #
TT#
005 #
TT#
006 #
TT#
007 #
TT#
008 #
VV#
009 #
LL#
099 #
Description of Command
‘Modify Master User Access Code (lock’s
activation)’ (Always 8 digits)
‘Date setup’ (MM = 01 to 12; DD = 01 to
31; YY = 00 to 99)
‘Time setup’ (HH = 00 to 23; MM =
00 to 59)
‘Lock ID setup’ (NNNN = 0000 to 9999)
‘Unlock time setup’ (TT = 02 to
20 seconds)
‘Passage Mode Timeout setup’ (TT = 01 to
24 hours - duration time in hours; 00 = no
time limit)
‘Tamper time setup’ (TT = 00 to 90 seconds)
‘Tamper wrong try setup’ (TT = 03 to 09)
‘Buzzer volume control’ (VV = 00 to 03; 00
= off; 01 = Low; 02 = Normal; 03 = High)
‘Modify access length’ (LL = 04 to 08 digits)
‘Reset to factory default values’, except
access code length. (Master, manager,
access user and time/date are retained if
already programmed. Users are not reset.)
Authorization
Master
Master
Master
Master
Master, Mgr
Master, Mgr
Master, Mgr
Master, Mgr
Master, Mgr
Master
Master