![Kaba E-Plex 5000 Operation Manual Download Page 27](http://html.mh-extra.com/html/kaba/e-plex-5000/e-plex-5000_operation-manual_649018027.webp)
23
Procedure 15 - De-activate Service User Access Code
A Service User Access Code should be de-activated for a certain time
period - during a Service User’s absence, for example, or if you created
an Access Code but have not yet assigned it to a Service User. A
Service User’s time period continues to decrement if the User has only
been de-activated, not deleted.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2. Enter Command
402# to de-activate a Service User Access Code.
3.
Enter the code
402#NNN#, where NNN is the specific Manager
ID location,
024 for example.
4. Example of Complete Entry:
402#025#.
5. Enter
another
# to indicate the end of programming.
6. You have now de-activated a Service User Access Code.
Procedure 16 - De-activate all Access Codes except Master,
Manager, M-Unit
You may need to de-activate all users, for example, during a plant shut-
down. This procedure will de-activate all regular User Access Codes
that are active, excluding Master, Manager, and M-Unit Codes.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command
498# to de-activate all Access and
Service Codes.
3.
Example of Complete Entry:
498#.
4.
Enter another
# to indicate the end of programming.
5.
You have now de-activated all regular User Access Codes.