24
PROCEDURE 10 - ACTIVATE SERVICE USER ACCESS
CODE
A Service User Access Code should be activated if it has been deactivated for a
certain time period - during a Service User’s vacation, for example.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
302#
for Service User Functional Code.
3. Enter the ID location
NNN#
, where
NNN
is the specific User ID location,
025
for example.
4. Example of Complete Entry:
302#025#
.
5. Enter another
#
to indicate the end of programming.
6. You have now reactivated a Service User Access Code.
PROCEDURE 11 - ACTIVATE ALL USER ACCESS CODES
You may need to activate all users if you have de-activated the whole group -
after a lockout, for example. This procedure will re-activate all regular and
Service User Access Codes that are temporarily inactive.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
398#
.
3. Example of Complete Entry:
398#
.
4. Enter another
#
to indicate the end of programming.
5. You have now reactivated all regular User and Service User Access Codes.
PROCEDURE 12 - ACTIVATE / DE-ACTIVATE PASSAGE
MODE
You have already programmed a default duration for a door to remain in
Passage Mode -
Procedure 5, Program the Duration of the Passage Mode
Period
, on page 9. When you activate Passage Mode, it becomes enabled
for the duration you have set in Procedure 5.
If your length is 6 hours, and you activate Passage Mode at 1:00, it will auto-
matically re-lock at 7:00. Even if the lock was taken in and out of Passage Mode
multiple times during the six hour period, it will still re-lock after six hours (pro-
grammable) from the original starting period. This ensures that a lock will never
remain in Passage Mode beyond the programmed time period of 1 to 24 hours.
Summary of Contents for E-PLEX 30XX SERIES
Page 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES ...
Page 19: ...Notes Notes 19 ...
Page 20: ...20 Notes ...
Page 21: ...21 Notes ...