23
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
299#
to delete all Access and Service User Codes.
3. Enter another
#
to indicate the end of programming.
4. You have now deleted all User Access and Service Codes, allowing you to
re-assign Access Codes from 0000{0000} to 9999{9999}, in ID loca-
tions from 001 through 299.
PROCEDURE 8 - ACTIVATE USER ACCESS CODES
A User Code should be activated if it has been de-activated for a certain time
period - during a user’s vacation, for example. User Codes that are inactive, but
might be needed some time in the future, should be de-activated rather than
deleted.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
300#
to activate a User Code.
3. Enter the ID location
NNN #
, where
NNN
is the specific User ID location,
023
for example.
4. Example of complete entry:
300 #023#
.
5. Enter another
#
to indicate the end of programming.
6. You have now activated the User Access Code assigned to 023.
PROCEDURE 9 - ACTIVATE MANAGER ACCESS CODE
A Manager Code should be activated if it has been de-activated for a certain
time period - during a Manager’s vacation, for example.
Required User Level: Master
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command
301#
to activate a Manager Access Code.
3. Enter the ID location
NNN#
, where
NNN
is the specific User ID location,
024
for example.
4. Example of Complete Entry:
301#024#
.
5. Enter another
#
to indicate the end of programming.
6. The Manager Access Code will now work in that door with all the access
privileges assigned to a Manager User.
Summary of Contents for E-PLEX 30XX SERIES
Page 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES ...
Page 19: ...Notes Notes 19 ...
Page 20: ...20 Notes ...
Page 21: ...21 Notes ...