12
F-3
Example of Complete Entry:
008#02#
.
F-4
Enter another
#
to indicate the end of programming.
F-5
The lock will now sound the buzzer at the desired volume
Normal, until you change it.
Users - General Information
1. Master and Manager Codes can do two different things:
• Open the door by entering the Access Code without
#
signs.
• Put the lock into Pushbutton Programming Mode by entering
#
before
and after their Access Code.
2. Each user (Manager User, Service User or Access User) occupies one of the
available 100 locations in the user table.
3. By default, user 000 is the Master User.
4. Users have a 15-second period to enter the entire key sequence, and 5 sec-
onds between pressing each pushbutton number. If they pause longer than
5 seconds between each pushbutton pressed, or exceed the 15-second
period to enter the total sequence, the lock:
• aborts the current programming sequence
• automatically exits the programming state
• sends the user a ‘Keypad Timeout’ feedback message
Note: Correct errors during a command sequence.
If an invalid entry
occurs, recover from the mistake by entering the (
*
) key, which will clear all
entries made from the beginning of the current command sequence, and will
reset the 15-second time limit for entering the code. In this case, you still
have 15 seconds from the first number entered to enter the whole code.
User Levels
Four different classifications of users can perform various operations at the lock.
Master User
- The Master User is the top-level manager who performs the ini-
tial lock setup activities and can program all lock functions. There is a maxi-
mum of one Master User per lock.
Manager
- A Manager can program all lock functions except:
• defining the Access User Code length
• modifying master user Access Code
• resetting to default value
• activating lockout mode
• adding / deleting / enabling / disabling a Manager User. The number of
Managers is limited only by available user table space (99 maximum
because one (000) is reserved for the Master Code).
Access User
- An Access User has the ability to open the lock. The number of
Access Users is limited only by available user table space (99 maximum
because one (000) is reserved for the Master Code).