7
DEFAULT VALUES OF THE E-PLEX 2000
PROGRAMMABLE PARAMETERS
Parameters
Factory Default Values
Lock state
Unprogrammed
Passage mode open time limit
9 hours
Passage mode
De-Activated
Lockout mode
De-Activated
Unlock time
2 seconds
Buzzer volume control
Low
Tamper shutdown time
30 seconds
Tamper attempt count
4 attempts
Access code length
4 digits
Master combination
12345678 (8 digits)
Access code
None
Code status
Activated
CONFIGURING THE LOCK
General Procedure for Pushbutton Programming
1. The pages that follow provide step-by-step instructions for programming the
E-Plex 2000/EPS2000 lock.
2. The general procedure for all programming functions is as follows:
a. Put the lock in Programming Mode by pressing # Master Code #
b. Use the Summary of Commands Table in the appendix section of this guide
to enter the three digit command sequence (Command Type + Function
Code), followed by #.
c. Enter the appropriate numbers as required.
d. Press # to end Programming Mode.
e. Once the lock is in programming mode, multiple command sequences can be
entered without having to repeat the #mastercode#. However, if there is no
activity for 15 seconds at the keypad, the lock will automatically exit from
programming mode.