background image

(P/N) 735.028 Rev M • 11/14 

© copyright 2006-2014 

Kaba Mas LLC

Page 1 of 8

ComboGard Pro locks can either be configured using the ComboGard Pro Setup software or through 
a series of keypad commands. This document will cover configuring the lock using the keypad 
commands ONLY. 

The ComboGard Pro Lock has three states of operation: 

Factory Default, Manual Setup, and 

Active. ComboGard Pro locks are shipped from LA GARD in Factory Default state without Users or 
features enabled. 

Factory Default: The Lock must be in the Factory Default state to be programmed by the PC 
software. 
Factory mode functions as follows: 
•  1 key – When pressed, will open the Lock. 
•  0 key – When pressed, prompts the ComboGard Pro Setup software to send the configuration 
  settings to the Lock. 
OR if pressed and held, places the Lock into Manual Setup. 
•  All other keys perform no function. 

Manual Setup: The Lock can be configured using the keypad only. 
Active: To activate the Lock and freeze the configuration, the Manager combination MUST 
be changed. 
WARNING: Add all required Users and complete Setup Configuration before changing the Manager’s 
default combination from 5-5-5-5-5-5. Once the combination is changed, NO ADDITIONAL USERS 
can be added.

PROGRAMMABLE LOCK FEATURES 
MODES
 (Multiple Modes may be selected.) 
• 

Silent Alarm (Alarm Box Required) 

  If enabled, this option will send a signal to an outside alarm system through the LA GARD 
  Alarm Box. 
• 

Dual Mode 

  If enabled, two combinations will be required to operate the Lock. 
  The Manager and one additional User must be active. 
• 

Time Delay Override 

  If enabled, User 9 can override delay period. 
  User 9 must be active. 

EXTERNAL SIGNALS (Alarm Box Required - P/N 2789NC. Only one External Signal type may 
be selected.)
An external input signal to the Alarm Box will either disable the Lock from opening, override the time 
delay, or enable the remote override depending on the selection programmed for External Signals.
•  External Signal disables Lock opening with valid combination.
NOTE: When configuring the ComboGard Pro Lock using the keypad only, the Disable Opening 
option is enabled by default and cannot be changed.

OR External Signal overrides Time Delay. (This option is ONLY available if enabled using Setup 
software.)
OR External Signal enables the Remote Override. (This option is ONLY available if enabled using 
Setup software, 

and with Lock code level 39E v1.09 or higher.)

KEYPAD ONLY SETUP INSTRUCTIONS

COMBOGARD

PRO

39E Electronic Combination Lock

Summary of Contents for LA GARD COMBOGARDPRO 39E

Page 1: ...from 5 5 5 5 5 5 Once the combination is changed NO ADDITIONAL USERS can be added PROGRAMMABLE LOCK FEATURES MODES Multiple Modes may be selected Silent Alarm Alarm Box Required If enabled this option...

Page 2: ...low and should be replaced immediately If the battery level becomes too low to safely operate the Lock pressing any key will initiate the low battery warning The battery must be replaced before the Lo...

Page 3: ...ill be permanently lost PROCESS IS AS FOLLOWS Action Press and hold 0 key for 3 seconds Result Lock beeps twice and the LED remains ON throughout the entire process Action Enter default code of 5 5 5...

Page 4: ...esired Lock Mode configuration to confirm NOTE Dual Mode cannot be selected if at least one additional User has not been enrolled User 9 must be enrolled to use the Time Delay Override function MODE T...

Page 5: ...m 5 The lock is now active and the configuration is frozen 6 Test lock operation several times before closing the door NOTE If default combinations are used it is recommended that they be changed New...

Page 6: ...P N 735 028 Rev M 11 14 copyright 2006 2014 Kaba Mas LLC Page 6 of 8 NOTES...

Page 7: ...P N 735 028 Rev M 11 14 copyright 2006 2014 Kaba Mas LLC Page 7 of 8 NOTES...

Page 8: ...Mas shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material 20...

Reviews: