(P/N) 757.118 Rev B 02/12 • © copyright 2004-2012
Kaba Mas LLC
Page 2 of 2
CHANGING YOUR COMBINATION
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter “zero” six times.
2. Enter your existing six (6) digit combination one time.
3. Enter your NEW six (6) digit combination two times.
4. If a mistake is made wait thirty (30) seconds and repeat steps
1 - 3.
5. Test lock operation several times before closing the door.
CAUTION: When selecting a combination do not use birthday or other predictable
data that could give correlation between the user and combination.
•
Valid Combination Entry - Double signal after valid six (6) digit combination
is entered.
•
Invalid Combination Entry - Triple signal indicates the old combination is
still valid.
BATTERY LOW WARNING
• Repeated LED flashing and beeping during an opening indicates that the battery
is low and needs immediate replacement.
• Uses one (1) 9-Volt alkaline battery only.
(Example: Duracell™ or Eveready™ alkaline
batteries.) The replacement of batteries at
least once annually is recommended.
If battery is depleted and will not allow lock
to open, follow instructions below. Lock
contains a non-volatile memory, even with
batteries removed the lock will retain all
programming.
CHANGING YOUR BATTERY
1. Slide the keypad housing up and carefully
pull away from mounting surface to expose
battery compartment.
2. Remove the old 9-Volt alkaline battery.
3. Remove the connector by unsnapping it from
the two terminals on the top of the battery.
CAUTION! Hold onto battery terminal connector to avoid
pulling the wires out of housing
4. Press and hold zero (0) key for ten (10) seconds before
installing a battery.
5. Carefully position the keypad over the
mounting screws and slide the keypad housing
down. Ensure there are no wires or cables
trapped between the input pad and the safe door.
Pinched cables can result in a short circuit.
Mounting Instructions available at www.kaba-mas.com.