Page 24
Branch 17 Aux 1 Mode
This is to select the type of output for Aux 1 Pin A7. The selection can be pulsed, timed for
10 seconds, latched on/off, or during hot start.
Branch 18 Aux 2 Mode
This is to select the type of output for Aux 2 Pin A6. The selection can be pulsed, timed for
10 seconds, latched on/off. Aux 2 can also be selected to supply an output if the Hot Alert
temperature has been reached even if the K9 system is not activated (can be used for indica-
tion while driving or fail safe.
Branch 19 Manual/Passive Alarm Arming
This is to select the alarm arming feature between manual (remote only) and passive (auto
armed after last door closes)
Branch 20 Auto Alarm Rearming
When selected, the system will automatically re-arm 30 seconds after it is disarmed .
Branch 21 Arming Chirps
Selects whether the siren will chirp when the alarm system is armed/disarmed. This function
can also be changed via the remote. See
Branch 22 No Selection
.
Branch 23 Door Unlock Pulse
Selects between one pulse or two pulse operation for the door unlock output. Many new im-
port vehicles
’
factory door locking systems require two pulses on the proper wire to unlock
the doors.
Branch 24 Door Lock Pulse Length
Selects between a 1, 3 or 0.1 seconds output for door locking and unlocking. Program to 3
seconds for vehicles equipped with vacuum door locking systems.
Branch 25 Passive Door Locking
Selects whether or not the system will automatically lock the doors during Passive Arming.
Branch 26 Lock after Start
When selected, the doors will automatically lock after remote starting.
Branch 27 Lock after Shutdown
When enabled, the doors will automatically lock after remote shutdown.