8
For Professional Technical Support call 1-844-242-2475
10. Battery backup system testing
To verify the system is operational, press “RESET” button 1–4 seconds. The system will complete a self-testing
diagnostic. The DC pump will run for 3 seconds.
Green light is on: The system is normal.
Yellow light quickly flashes and alarm sounds: Battery disconnected or DC fuse blown. Connect the battery or
replace the fuse.
Yellow light slowly flashes and alarm sounds: Power off or power adaptor failed.
Yellow light is on: Battery recharging.
Red light is on and the alarm sounds: Battery backup pump working.
Red light slowly flashes and alarm sounds: Pump wire connection problems or pump failed.
NOTE:
Do not reduce size of discharge pipe or hose below 1 1/4” (3.2 cm) diameter. If discharge is too small,
pump will overheat and fail prematurely. This pump is designed for use as a residential sump only. Only pump
water with this pump.
11. Once all wiring is complete, fill your pit with water and verify that the PSP removes the water and the BSP
doesn't run. Then, unplug your PSP and refill your pit with water. Verify that the BSP removes the water.
OPERATION
Risk of electric shock
. Can shock, burn or kill. Do not handle a pump or pump motor with wet hands
or when standing on wet or damp surface, or in water.
1. Shaft seal depends on water for lubrication. Do not operate pump unless it is submerged in water as seal may
be damaged if allowed to run dry.
2. Motor is equipped with automatic reset thermal protector. If temperature in motor should rise, switch will cut off
all power before damage can be done to motor. When motor has cooled, switch will reset automatically and
restart motor. If protector trips repeatedly, pump should be removed and checked. Low voltage, long extension