background image

6                                                                                                                               

For Professional Technical Support call 1-844-242-2475 

NOTICE

: Remove all sand, clay, and gravel before installing. 

5. Install the outlet pipe on the quick connector. 

NOTICE

: The quick connector must be tightened. 

 

6. Place Combo Kit into sump pit. Make sure vertical float switches can operate freely inside sump pit, once the 

Combo Kit is firmly seated in the base of the pit, then connect the pump outlet pipe to the top outlet pipe with a 

hose clamp assembly. 

 

7.

 

Secure power cord around pipe with a cable tie. Plug the primary pump into a standard household 15 amp 

outlet. 

NOTICE

: The circuit should be dedicated to the sump pump exclusively. 

Remember: Do not handle the pump while it is plugged in; whether it is running or not. 

 

 

Summary of Contents for Primary Series

Page 1: ...IMARY AND BACKUP PUMP SYSTEM Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 2019 Copyright GP Enterprises Co Ltd Rev 11 6 19 Model SPC03301K ...

Page 2: ...ecure the discharge line before starting the pump An unsecured discharge line will whip possibly causing personal injury and or property damage 7 Extension cords may not deliver sufficient voltage to the pump motor Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water The use of an extension cord to power this pump is not ...

Page 3: ...dequate electrical power to the pump dirt or debris may cause the pump to fail Please carefully read the manual and follow the instructions regarding common pump problems and remedies PRE INSTALLATION GENERAL INFORMATION The Battery Backup Combo Kit is pre plumbed up to the hose and clamp assembly The system includes the primary sump pump PSP backup sump pump BSP assembly and vertical float switch...

Page 4: ...imary and backup pump system is designed for home sump applications Use this pump only for pumping water This unit is not designed as a waterfall or fountain pump or for applications involving salt water or brine Use with waterfalls fountains salt water or brine will void warranty Do not use where water recirculates Not designed for use as a swimming pool drainer TOOLS REQUIRED MATERIALS REQUIRED ...

Page 5: ...pump OR B No piggyback switch Reset the circuit breaker or reinstall the fuse and use a non conducting broom handle or stick to raise the float switch the pump should start Drain the pit and then release the switch When the pit has drained turn off open the circuit breaker or remove the fuse again to avoid electrical shock while working on the installation Unplug existing sump pump and place power...

Page 6: ...al float switches can operate freely inside sump pit once the Combo Kit is firmly seated in the base of the pit then connect the pump outlet pipe to the top outlet pipe with a hose clamp assembly 7 Secure power cord around pipe with a cable tie Plug the primary pump into a standard household 15 amp outlet NOTICE The circuit should be dedicated to the sump pump exclusively Remember Do not handle th...

Page 7: ...x wiring and set up 1 Plug the pump wire male terminal into the female terminal PUMP on the control box 2 Plug the float switch male terminal into the female terminal FLOAT on the control box 3 Plug the 12 V adaptor outlet plug into the power connector POWER on the control box Plug the adaptor into a 115 V GFCI power outlet The LED indicators on the control box screen should be on 4 Follow the on ...

Page 8: ...o small pump will overheat and fail prematurely This pump is designed for use as a residential sump only Only pump water with this pump 11 Once all wiring is complete fill your pit with water and verify that the PSP removes the water and the BSP doesn t run Then unplug your PSP and refill your pit with water Verify that the BSP removes the water OPERATION Risk of electric shock Can shock burn or k...

Page 9: ...cture for long life with minimum maintenance Reliable reed sensor water detection for automatic operation Includes controller charger float switch pump and battery box Easy installation without any major plumbing changes CARE AND MAINTENANCE To prevent serious injury from accidental operation unplug the pump from its electrical outlet before performing any inspection maintenance or cleaning proced...

Page 10: ...he intake screen and the impeller Pump operates but delivers little or no water Low line voltage If voltage under recommended minimum check size of wiring from main switch on property If OK contact power company or hydro authority Something caught in impeller Remove the pump and clean out the impeller Worn or defective parts or plugged impeller Clean impeller if plugged otherwise replace pump BATT...

Page 11: ...n Qty 1 shaft 1 2 impeller 1 3 Gasket 1 4 Bottom plate 1 5 screws 8 REPAIR PARTS BATTERY BACKUP UNIT Ref Description Qty 1 quick connector 1 2 Combo Plumbing 1 3 Primary Pump check valve 1 4 Backup pump check valve 1 5 DC Backup pump 1 6 Gasket 1 7 impeller 1 8 volute 1 9 Battery box 1 10 adaptor 1 ...

Page 12: ...ct to a K2 Sales and Service Center for warranty service cost of shipping will be paid one way This warranty does not apply to products purchased outside of the United States including its territories and possessions outside of U S Military Exchange and outside of Canada This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of K2 prod...

Reviews: