4 For Professional Technical Support call 1-844-242-2475
caution when installing and programming to limit the pump's performance potential with old or questionable
equipment. This appliance is not intended for use by persons (including children) of reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning the use of the appliance by a person responsible for their safety.
14.
CAUTION
: Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition,
all Occupational Safety and Health Administration (OSHA) guidelines must be followed.
15.
IMPORTANT
:
To minimize the risk of injury due to suction entrapment hazard: Pools and spas should utilize a
minimum of two drains per pump. A properly installed and secured ANSI/ASMEA112.19.8 approved anti-
entrapment suction cover must be used for each drain. Each suction cover must be installed at least three (3’)
feet apart, as measured from the nearest point to nearest point. Regularly inspect all covers for cracks, damage
and advanced weathering. If a cover becomes loose, cracked, damaged, or broken, or is missing, close the pool
or spa immediately, shut off the pump, post a notice and keep the pool or spa closed until an appropriate certified
cover is properly installed. Replace drain covers as necessary. Drain covers deteriorate over time due to
exposure to sunlight, pool chemicals and weather. Avoid getting hair, limbs or body in close proximity to any
suction cover, pool drain or outlet. Disable suction outlets or reconfigure into return inlets.
16.
IMPORTANT
:
Before pressure testing, make the following safety checks: Check all clamps, bolts, lids, and
system accessories before testing. Release all air in system before testing. Tighten pump trap lids to 30 ft. lbs.
(4.1 kg-m) torque for testing. Water pressure for test must be less than 25 PSI (7.5 kg/cm2). Water temperature
for test must be less than 100° F (38 °C). Limit test to 24 hours. After a test, visually check the system to ensure
that it is ready for operation. Remove the trap lid and re-tighten it by hand only.
NOTICE
: These testing parameters apply only to the models described herein. For other equipment, consult the
manufacturer.
PRE-INSTALLATION
APPLICATION
This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do
not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it
cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for
storage and reassembled to its original integrity.
TOOLS REQUIRED
Phillips
Screwdrive
Flathead
Screwdrive
Wrenc
h
Safety
Goggles
Pipe Wrench
Hacksaw
Tape
Measure
Thread Tape
PVC Glue