6                                                                                                                    For Professional Technical Support call 1-844-242-2475 

 

 

Allow use of short, direct suction pipe (to reduce friction losses). 

 

Allow for gate valves in suction and discharge piping. 

 

Have adequate floor drainage to prevent flooding. 

 

Be protected from excess moisture. 

 

Allow adequate access for servicing pump and piping. 

WARNING: Risk of fire and burns. 

Can cause severe injury, property damage or death. Motors run at high 

temperatures. To reduce the risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump 
motor. To avoid burns when handling the motor, let it cool for 20 minutes before trying to work on it. 

NOTICE

: When connecting pipe to pump with union half, use PTFE tape between pipe and union adapter. Union 

collar to pump should be assembled dry and hand-tightened. 

 

 
Thread sealant tape instructions: 

 

Use only new or clean PVC pipe fittings.

 

 

 

Wrap male pipe threads with one to two layers of PTFE tape. 
Cover entire threaded portion of pipe. 

 

Do not overtighten or tighten past thread stop in pump port! 

 

If leaks occur, remove pipe, clean off old tape, rewrap with one 
to two additional layers of tape and remake the connection. 

NOTICE

: Support all piping connected to pump! 

 

 

Piping 

 

Use at least 1-1/2 in. (38 mm) pipe (Use 2 in. (51 mm) pipe if 
possible). Increase size if a long run is needed. 

 

To avoid strains on the pump, support both suction and discharge pipes independently. Place these supports near 
the pump. 

 

To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the 
pump. 

 

To avoid air locking, slope suction pipe slightly upward toward the pump. 

 
NOTICE

: To prevent flooding when removing pump for service, all flooded suction systems must have gate valves in 

suction and discharge pipes. 

 

Pool Pump Suction Requirements 

 

WARNING

Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or operate swimming 

pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. Follow the guidelines below for a pump 
installation which minimizes risk to users of pools, spas, and hot tubs. 

Entrapment Protection 

The pump suction system must provide protection against the hazard of suction entrapment or hair 
entrapment/

entanglement. 

Suction Outlet Covers 

 

All suction outlet covers must be maintained. They must be replaced if cracked, broken, or missing. 

 

See Testing and Certification for outlet cover certification requirements. 

 

All suction outlets must have correctly installed, screw fastened covers in place. 
 

Summary of Contents for PPI10001SPK

Page 1: ...R S MANUAL 2 SPEED POOL PUMP Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 www K2pumps com Copyright 2020 GP Enterprises Co Ltd K2Man 31 Rev 12 28 20 ...

Page 2: ...of the body is held against the drain cover trapping the swimmer underwater This hazard is present when the drain cover is missing or broken or the cover flow rating is not high enough for the pump or pumps Evisceration Disembowelment When a person sits on an open pool particularly a child wading pool or spa outlet and suction is applied directly to the intestines causing severe intestinal damage ...

Page 3: ...ested equipment may fail causing severe injury or property damage Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional perform all pressure tests Do not connect system to a high pressure or city water system Use equipment only in a pool or spa installation Trapped air in the system can cause explosion BE SURE all air is out of the ...

Page 4: ... cover is properly installed Replace drain covers as necessary Drain covers deteriorate over time due to exposure to sunlight pool chemicals and weather Avoid getting hair limbs or body in close proximity to any suction cover pool drain or outlet Disable suction outlets or reconfigure into return inlets 16 IMPORTANT Before pressure testing make the following safety checks Check all clamps bolts li...

Page 5: ... 1 2 in Slip Half Union Kit included with the pump Only qualified licensed personnel should install pump and wiring Pump mount must Be located away from corrosive or flammable liquids Have enough ventilation to maintain air temperature at less than the maximum ambient temperature rating Max Amb listed on the motor model plate If this pump is installed in an enclosure pump house the enclosure must ...

Page 6: ...ICE Support all piping connected to pump Piping Use at least 1 1 2 in 38 mm pipe Use 2 in 51 mm pipe if possible Increase size if a long run is needed To avoid strains on the pump support both suction and discharge pipes independently Place these supports near the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump To avoid air l...

Page 7: ...on outlet is completely blocked The flow through the remaining main drain s must comply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification Suction outlet covers must have been tested by recognized testing laboratory and found to comply with the latest ASME ANSI Specifications for Suction ...

Page 8: ...ire required by code Connect motor ground terminal to electrical service ground Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 ft 1 5 m of the inside walls of swimming pool spa or hot tub To Wire a Two Speed Motor NOTIC...

Page 9: ...otor to prevent dirt bugs etc from entering Table l Recommended Fusing Data Motor HP Branch Fuse Rating Amps Max Load Amps Voltage Hz Phase Service to Motor Distance in Ft m 0 300 0 90 AWG Wire Size mm2 1 15 5 1 230 60 1 14 2 1 1 2 15 6 6 230 60 1 Time delay fuses are recommended instead of standard fuses in any motor circuit OPERATION STORAGE WARNING Risk of explosion Before removing trap cover N...

Page 10: ...pa system Propylene glycol or RV antifreeze is non toxic and will not damage plastic system components other anti freeze formulas are highly toxic and may damage plastic components in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see Draining Pump Keep motor dry and covered during storage To avoid condensation corrosion pr...

Page 11: ...egular maintenance is needed beyond reasonable care and periodic cleaning of the strainer basket If shaft seal is worn or damaged repair as follows Pump Disassembly Removing Old Seal Before disassembly disconnect power to pump motor Be sure gate valves on suction and return piping are closed Release all pressure by opening all vents 1 Drain pump by removing drain plugs on bottom of pump body and t...

Page 12: ...k 4 Replace slinger on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it 5 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque 6 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 7 Slide rotating seal member polished carbon face out over impeller sleeve until rubber...

Page 13: ... is not clogged if it is clean trap and strainer Make sure impeller is not clogged follow instructions in Removing Old Seal check impeller for clogging follow instructions in Installing New Seal for reassembly Impeller and diffuser may be worn If so order replacement parts by calling customer service Problem Possible Cause Corrective Action The pump may be running too slow There is an error in the...

Reviews: