Docu-No.: 1090020601-EN Rev. 1.2.1
Page 55
Installation 4
Power wiring; specific requirements 4.13
4.13.4
Shielding and cable glands
▲
For operation in the allowed hazardous zone, only use certified
explosion-proof cable glands and blind covers ATEX category
2GD on the KCM.
Connect the shields of all cable connections to low-impedance
equi-potential bonding (
<
0.1 ohm) via the cable glands on both
sides.
Lay the shielding (1) evenly over the O-ring (2).
If the KCM SS used in conjunction with the Hygiene mounting
must be read the instructions in section
Fig. 4.19
Cable gland shielding